Troubleshooting with raid manager – HP XP RAID Manager Software User Manual
Page 57

Troubleshooting with RAID Manager
To identify the cause of errors while using RAID Manager, you can use the following logs:
•
The log is shown in the RAID Manager window.
For more information, see
“Identifying errors using the log on the RAID Manager window”
.
•
The RAID Manager operation log file.
For more information, see
“Identifying errors using the RAID Manager operation log file”
The following table lists the error codes for SSB1: B901, B9A8, B9A9, B9AD, B9AE, and 2E31.
For more information about the error codes that are not described in this table, contact HP Technical
Support.
Cause of error
RAID Manager command
SSB2
You cannot run the command because the storage system did not perform user
authentication.
All commands
9100
You cannot create the pair because of a shortage of pair tables.
paircreate
9685
You cannot create the pair because of a shortage of differential tables.
paircreate
9686
You cannot create the pair because the pool is not available.
paircreate
9700
You cannot create the pair because a pair using a pool ID that is different from
the specified pool ID exists in the specified P-VOL.
paircreate
9702
You cannot create the pair because another FS or SS S-VOL is using the volume
you specified as the P-VOL.
paircreate
9703
You cannot create the pair because another FS or SS P-VOL is using the volume
you specified as the S-VOL
paircreate
9704
You cannot create the pair because another FS or SS S-VOL is using the volume
you specified as the S-VOL.
paircreate
9705
You cannot create the pair because another SS pair is using the specified SS
ID.
paircreate
9706
You cannot create the pair because the capacity of the pair that you are trying
to create exceeds the licensed capacity.
paircreate
9707
The command ends abnormally. You tried to use a command other than the
paircreate
command for the volume in the pair other than the SS pair.
All commands
9718
This error can also occur when you run the command with an unsupported
parameter.
The command ends abnormally because the pair is in a status that the command
does not accept, or because you ran the command with an unsupported
parameter.
All commands
9719
You cannot create the pair because you do not have a sufficient amount of
shared memory.
paircreate
971a
The pair cannot be restored because the volume you specified as the P-VOL has
an S-VOL Disable attribute.
pairresync -restore
971f
An error occurred for one of the following reasons:
All commands
9720
•
You specified an LDEV number for the P-VOL or S-VOL that is not correct.
•
You specified a P-VOL or S-VOL that is not paired.
•
The P-VOL or S-VOL is specifying a pair that is not ready for the specified
operation.
•
You specified an MU number (SS ID) that is not correct.
Troubleshooting with RAID Manager
57