Required status
RAID Manager pair operation
PSUS/PFUS, PSUE
pairresync
PSUS/PFUS
pairresync -restore
PAIR/PFUL, PSUS/PFUS, PSUE
pairsplit -S
If you run a command for a pair with a status other than the one required, you can get mixed
results. The following table lists the results for RAID Manager commands that you run that have
statuses other than those that are required.
RAID Manager command
Status
pair split-E
pair split-S
pair
resync-restore
pair resync
pair split
pair
create-split
pair create
Ab
Np
Ab
Ab
Ab
Ab
Ok
SMPL
Ab
Ab
Np
Np
Ab
Ab
Np
COPY
Ab
Ok
Np
Np
Ok
Ok
Np
PAIR/PFUL
Ab
Ok
Ok
Ok
Np
Np
Ab
PFUS
Ab
Ab
Np
Np
Ab
Ab
Np
RCPY
Np
Ok
Ab
Ok*
Ab
Ab
Ab
PSUE
Ok: Ends normally
Np: Not performed but ends normally
Ab: The command is rejected, ends abnormally
* If you run the pairresync to a pair in “PSUE” status because you cannot reserve shared memory for the S-VOL management
area, the command is rejected and ends abnormally.