Auto lun v2 – HP XP RAID Manager Software User Manual
Page 33
![background image](/manuals/398014/33/background.png)
The following table shows the relationship between Cnt Ac-S/Cnt Ac-J pair operations and SS
status.
SS status
Cnt Ac-S / Cnt Ac-J operations
PSUE
RCPY
COPY
2
PSUS, PFUS
PAIR,
PFUL
COPY
1
No
No
No
No
No
No
Create pair 3
Yes
N/A
Yes
Yes
Yes
Yes
Split pair
Yes
N/A
Yes
Yes
Yes
Yes
Resync pair
Yes
N/A
Yes
Yes
Yes
Yes
Delete pair
Yes
N/A
Yes
Yes
Yes
Yes
Switch operations to the remote
site
1.
“COPY” is the status during the initial copy.
2.
“COPY” is the status during a resynchronization.
3.
To use a Cnt Ac-S or Cnt Ac-J S-VOL as the SS P-VOL, you must first create the Cnt Ac-S or Cnt Ac-J pair then create
the SS pair.
To view a list of the corresponding RAID Manager pair status names, see
and RAID Manager pair status names” (page 67)
Cnt Ac-S and Cnt Ac-J volume backup in 3DC multi-target configuration
You can use SS to back up Cnt Ac-S and Cnt Ac-J volumes on the remote sites in a 3DC multi-target
configuration.
The following figure shows how to back up the volumes.
Pair 1 is the Cnt Ac-S pair. Pair 2 is the Cnt Ac-J pair. Pair 3 is the Cnt Ac-J pair for a delta
resynchronization. Pair 4, pair 5, and pair 6 are the SS pairs.
To back up the volumes, complete the following:
1.
Create the 3DC multi-target and delta resynchronize pairs (pairs 1, 2, and 3).
2.
Create pair 4.
3.
Create pairs 5 and 6.
NOTE:
You cannot share SS volumes in 3DC Cnt Ac-J/Cnt Ac-J configurations.
Auto LUN V2
To share the source Auto LUN V2 pair with an SS P-VOL, complete the following:
Auto LUN V2