6.

Verify the settings in the Preview dialog box (see “

Preview Dialog Box

” on page 57).

7.

Click Apply in the Volume Operation window.

The settings are applied to the local storage system and the Volume Operation window is

displayed normally. When an error occurs, an error message is displayed. Verify the details

in the Preview dialog box.

Changing the Inflow Control Setting of the External Volume

You can change the inflow control setting of the external volume in the Volume Operation window. To

change the inflow control setting of the external volume, you need to right-click the external volume, click

the Inflow Control in the pop-up menu, and then click Enable or Disable.
To change the inflow control setting of the external volume:

1.

Start Remote Web Console, and open the Volume Operation window.

2.

Make sure that Remote Web Console is in Modify mode.

3.

Click the path group in the Volume Operation tree.

4.

Right-click the external volume that you want to change in the Volume Operation list.

A pop-up menu is displayed.

5.

Click Inflow Control in the pop-up menu and click Enable or Disable in the submenu.

The settings are displayed in blue and italics.

6.

Verify the settings in the Preview dialog box (see “

Preview Dialog Box

” on page 57).

7.

Click Apply in the Volume Operation window.

The settings are applied to the local storage system and the Volume Operation window is

displayed normally. When an error occurs, an error message is displayed. Verify the details

in the Preview dialog box.

Changing the Port Setting of the External Storage System

You can change the setting of the port of the external storage system in the Path Operation window. For

changing the setting of the port, use the Change WWN Parameter dialog box.

Caution:

If the default setting has no problem, use the default setting as it is.

Caution:

For the volume used in usual I/O, set IO TOV within 15 seconds.

Caution:

For changing the setting, match the value to the recommended value of the external storage

system.
To change the port setting of the external storage system:

1.

Start Remote Web Console, and open the Path Operation window.

2.

Make sure that Remote Web Console is in Modify mode.

3.

Select Fibre - External Subsystem from the drop-down list above the Path Operation tree.

4.

Click the product name in the Path Operation tree.

5.

Right-click the WWN that you want to change the setting in the Path Operation list.

A pop-up menu is displayed.

6.

Click Change WWN Parameter in the pop-up menu.

The Change WWN Parameter dialog box is displayed (see

Figure 44

on page 95).

7.

Change the set parameter of the selected port on the Change WWN Parameter dialog box.

8.

Click OK to close the Change WWN Parameter dialog box.

You are returned to the Path Operation window. The selected items are displayed in blue and

italics.

9.

Verify the settings in the Preview dialog box (see “

Preview Dialog Box

” on page 57).

10.

Click Apply in the Path Operation window.

94

Performing External Storage Operations