Error

Corrective Action

- Response error

Status: The external storage system is in the blocked status

caused by the abnormal reply (Response). You may not be able

to access the device of the external storage system. Or data

protection may be set on the device of the external storage

system.
Reaction: The port of the external storage system is recognized.

Check the setting and status of the external storage system. If

you cannot restore the path, call HP technical support.

- Initiator port

Status: The port attribute of the external storage system has been

changed to the initiator port.
Reaction: Set the port attribute of the external storage system to

the target port. If you cannot restore the path, call HP technical

support.

- Unknown port

Status: The port attribute of the external storage system is

unknown.
Reaction: The port of the external storage system is recognized.

Check the condition of the connection (for example, cables,

switches) to the external storage system. If you cannot restore the

path, call HP technical support.

- Cannot detect

port

Status: The path has been removed or the port of the external

storage system cannot be found. There is a problem with

connection to the external storage system. The following are

possible causes:

The fibre cable is not physically connected in the proper way.

The setting of the topology does not match between the

external port and the target port.

Because the security is set on the port, the device of the

external storage system cannot be recognized from the local

storage system.

If the external storage system is connected through switches,

the settings for the switches may not be appropriate.

Reaction: Check the condition of the connection to the external

storage system. If you cannot restore the path, call HP technical

support.

- Internal error

Status: The program error occurred. Or there is a logical

contradiction.
Reaction: Please call HP technical support.

- Timeout

Status: The processing was retried because the abnormal reply

(Response) was returned, however, the processing has been

stopped by timeout.
Reaction: The port of the external storage system is recognized.

Check the condition of the connection (for example, cables,

switches) to the external storage system. If you cannot restore the

path, call HP technical support.

- Target error

Status: An error such as the blockade of the controller has been

found in the port of the external storage system
Reaction: Check the status of the ports of the external storage

system. If you cannot restore the path, call HP technical support.