HP XP External Storage Software User Manual
Page 86
Table 17 Status of the Mapping Paths in the Mapping Path Information Dialog
Box
Displayed Item
Description
Normal
The mapping path is normal.
-
The status of the mapping path is not retrieved yet. Click Status in the Volume
Operation window to display the status of the mapping path.
Unknown
The status of the mapping path is unknown.
Blockade
The mapping path is blocked.
External device
setting changed
The setting of the external storage system has been changed. For example, the
path definition was deleted, or the external storage system itself was replaced
by another device.
LDEV size reduced
The setting of the volume capacity of the external storage system has been
changed (the volume capacity was reduced).
Not ready
The reply of the external storage system was NOTREADY.
Illegal request
The reply of the external storage system was ILLEGALREQUEST.
Command aborted The reply of the external storage system was ABORTEDCOMMAND.
Busy
The external storage system is in the BUSY status.
LDEV reserved
The external storage system is in the Reserve status.
Response error
The external storage system is in the blocked status caused by the abnormal
reply (Response).
Initiator port
The port attribute of the external storage system has been changed to the
initiator port.
Unknown port
The port attribute of the external storage system is unknown.
Cannot detect port
The path has been removed or the port of the external storage system cannot
be found.
Internal error
The program error occurred. Or there is a logical contradiction.
Timeout
The processing was retried because the abnormal reply (Response) was
returned, however, the processing has been stopped by timeout.
Standby
The port of the external storage system is standing by. The port status is normal
but cannot receive I/O.
Target error
Port failures, such as controller blockade are detected on the external storage
system side.
Checking
The processing of checking the mapping path status is in progress.
Disconnect
Connecting to the external storage system or the external volume is intentionally
stopped using the Disconnect Subsystem command or the Disconnect Volume
command.
Unavailable
The reply of the external storage system was Unavailable. The external storage
system demands to change the connected port. Once the status becomes
Unavailable, the primary path is changed to the alternate path that is in the
Standby status. When the primary path has been changed, the status of the
path becomes Normal.
Backoff
The reply of the external storage system was Backoff. The status of the path is
waiting for recovery because a temporary error has occurred in the volume of
the external storage system. Even if the status of the primary path becomes this
status, the primary path is not changed to the alternate path immediately. After
the error recovery, the status becomes Normal. If the status cannot be recovered
from the error, the path status is changed to the other status.