beautypg.com

HP XP External Storage Software User Manual

Page 110

background image

Error

Corrective Action

- Unavailable

Status: The reply of the external storage system was Unavailable.

The external storage system demands to change the connected

port. Once the status becomes Unavailable, the primary path

is changed to the alternate path that is in the Standby status.

When the primary path has been changed, the status of the

path becomes Normal.
Reaction: If the path is not changed over properly, check the

status of the external storage system. If you cannot restore the

path, call HP technical support.

- Backoff

Status: The reply of the external storage system was Backoff. The

status of the path is waiting for recovery because a temporary

error has occurred in the volume of the external storage system.

Even if the status of the primary path becomes this status, the

primary path is not changed to the alternate path immediately.

After the error recovery, the status becomes Normal.
Reaction: If the status cannot be recovered from the error, the

path status is changed to another status. React to the new path

status after the status is changed. If you cannot restore the path,

call HP technical support.

The volume in the

external storage

system cannot be

found even after

the Port Discovery

or the Volume

Discovery was

performed.

Remove the error and retry the operation.
The factor of the error could be as follows:

Remote Web Console is not in the Modify mode.

Port of the local storage system and the port of the external storage system

are not connected.

Port security is set on the external storage system.

The device in the external storage system is not in the Normal status.

External storage system is not connected to the port set to External of the local

storage system.

The capacity is not enough (capacity is less than about 38 MB (77,760 blocks)).

The cable for the switch is not connected appropriately.

The zoning for the switch is not set appropriately.

If none of the above corresponds to the actual factor, disconnect the cable

between the storage system and the external storage system once and connect it

appropriately again. After 30 seconds, retry the operation.

The external volume

is blocked.

Remove the error and retry the operation.
The factor of the error could be as follows:

All the set paths are blocked (paths are not connected).

The attribute of external volume is not set to Read/ Write attribute.

The external volume is blocked by error.

The Check Paths &

Restore Volume

command is

executed and you

have waited more

than 10 minutes,

but the status of

the device does

not change from

Checking.

Click Refresh ( ) command on the Remote Web Console main window while the

Status button is depressed. If the device status remains as Checking even though

you have updated the information, execute the Check Paths & Restore Volume

command again.
If the same problem persists despite retrying, call HP technical support.

110

Troubleshooting

This manual is related to the following products: