Path Status and Examples of Recovery Procedure (For Thunder 9500V Storage
System)
This section describes errors which requires recovery operation on the external storage system
side when the path status is not normal. When the path status is not normal, see the following
table to recover the path status. For the other errors which are not described in this section, see
Troubleshooting for External Storage
” on page 107. If you cannot restore the path, call HP technical
support.
Table 28 Path Status and Examples of Recovery Procedure (For Thunder 9500V
Storage System)
Path Status
Examples of Recovery Procedure
External device setting
changed
Settings of the LU paths may have been changed by LUN Manager.
Check the settings of the LU paths. If the settings of the LU paths have been
changed, change the settings back to the ones when the volume is mapped.
Or use External Storage to perform the Delete LU operation and perform
the Add LU operation again.
The access attribute of the volume may have been changed by Data Retention
Utility.
Check the access attribute of the volume. If the volume is protected by the
access attribute, release the protection.
Illegal request or
Response error
The volume may have been set as a pair volume for data copy.
Check if the volume is set as a pair volume of Business Copy, Continuous
Access or some other copy program. If the volume is set as a pair volume,
the volume may be protected because of the pair status. When the volume is
protected, change the pair status or delete the pair.
The access attribute of the volume may have been changed by Data Retention
Utility.
Check the access attribute of the volume. If the volume is protected by the
access attribute, release the protection.
Cannot detect port
There is a problem with connection to the external storage system. The
following are possible causes:
•
The fibre cable is not physically connected in the proper way.
•
The setting of the topology does not match between the external port
and the target port.
•
If the external storage system is connected through switches, the settings
for the switches may not be appropriate.
Check if the fibre cable is connected properly, and then set the Fibre Channel
port properly using LUN Manager.
The host group security may have been enabled by LUN Manager.
Check if the host group security is enabled or not. If the host group security is
enabled, disable the host group security.
USP V Storage System
When you connect a USP V storage system as the external storage system, you need to set the port to the
host group for the Windows hosts (host mode 0C: Windows, host mode 2C: Windows Extension).
Also, the port attribute must be the target port or the RCU target port.
Path Status and Examples of Recovery Procedure (For USP V Storage System)
This section describes errors which requires recovery operation on the external storage system
side when the path status is not normal. When the path status is not normal, see the following
table to recover the path status. For the other errors which are not described in this section, see