[Check ON/OFF] .........Set the check box to ON to select all the items (to set all the check boxes to ON (

;)). Set

the check box to OFF (

†) to release the selection of all the items (to set all the check boxes

to OFF (

†)).

Table 9-12 < Status output setting >

Item Content

Output

Select from Not use, + Total pulse, – Total pulse, Full scale 2, Alarm, Flow switch,
Total switch, AO range over, Pulse range over, and – Flow direction.

Alarm

Select from All, Hardware error, and Process error (when alarm is selected for DO1
output).

Flow rate switch

Select from Upper flow rate limit (Flow switch High) and Lower flow rate limit
(Flow switch Low) (when flow rate switch is selected for DO1 output).

Flow switch High

Enter in the range from 0 to 32 m/s or equivalent. (Use the same unit as the range
unit.)

Flow switch Low

Enter in the range from 0 to 32 m/s or equivalent. (Use the same unit as the range
unit.)

DO1

Total switch

Enter in the range from 0 to 99999999. (Use the same unit as the total unit.)

Output

Select from Not use, + Total pulse, – Total pulse, Full scale 2, Alarm, Flow switch,
Total switch, AO range over, Pulse range over, and – Flow direction.

Alarm

Select from All, Hardware error, and Process error (when alarm is selected for DO1
output).

Flow rate switch

Select from Upper flow rate limit (Flow switch High) and Lower flow rate limit
(Flow switch Low) (when flow rate switch is selected for DO1 output).

Upper flow rate limit
(Flow switch High)

Enter in the range from 0 to 32 m/s or equivalent. (Use the same unit as the range
unit.)

Lower flow rate limit
(Flow switch Low)

Enter in the range from 0 to 32 m/s or equivalent. (Use the same unit as the range
unit.)

DO2

Total switch

Enter in the range from 0 to 99999999. (Use the same unit as the total unit.)

Output

Select from Not use, + Total pulse, – Total pulse, Full scale 2, Alarm, Flow switch,
Total switch, AO range over, Pulse range over, and – Flow direction.

Alarm

Select from All, Hardware error, and Process error (when alarm is selected for DO1
output).

Flow rate switch

Select from Upper flow rate limit (Flow switch High) and Lower flow rate limit
(Flow switch Low) (when flow rate switch is selected for DO1 output).

Upper flow rate limit
(Flow switch High)

Enter in the range from 0 to 32 m/s or equivalent. (Use the same unit as the range
unit.)

Lower flow rate limit
(Flow switch Low)

Enter in the range from 0 to 32 m/s or equivalent. (Use the same unit as the range
unit.)

DO3

Total switch

Enter in the range from 0 to 99999999. (Use the same unit as the total unit.)

DO1 contact operation

Select ON at operation or OFF at operation.

DO2 contact operation

Ditto

DO3 contact operation

Ditto

Table 9-13 < Status input setting >

Item Content

DO1 input

Select from Not use, Total reset, and Zero calibration.

DO2 contact operation

Select ON at operation or OFF at operation.

Bulletin F-107-UXF3-S