3 word data [read-out only]: function code [04h, Bulletin f-107-uxf3-s – Dwyer UXF3 User Manual
Page 34
- 30 -
7.2.3
Word data [Read-out only]: Function code [04H]
Relative
address
Register
No.
Data
type
Parameter
Read-out data/Write-in data setting range
Remarks
3XXXX
0000 30001
float Velocity
Metric system: 32-bit floating data, Unit: m/s
English system: 32-bit floating data, Unit: ft/s
0004
30005 float
Flow rate
32-bit floating data
Unit: Flow rate
0008
30009 float
Flow rate %
32-bit floating data, Unit: %
000C
30013 double
+ Total value
64-bit floating data
Unit: Total
0014 30021
double
Total value
64-bit floating data
001C
30029 long
+ Total pulse
No decimal point, Unit: Pulse
0020 30033
long
Total pulse
No decimal point, Unit: Pulse
0024 30037
unsigned
int
RAS information
Data of hexadecimal number
0026 30039
int
Not
use
0028 30041
int
Not
use
002A 30043
int
Not
use
002C 30045
int
Not
use
002E 30047
int
Not
use
0030 30049
int
Wedge
S.V.
Metric system: No decimal point, Unit: m/s
English system: No decimal point, Unit: ft/s
0032
30051 int
Wedge incidence angle
1 place after decimal point, Unit: º
0034 30053
int
Pipe
S.V.
Metric system: No decimal point, Unit: m/s
English system: No decimal point, Unit: ft/s
0036
30055 int
Pipe incidence angle
1 place after decimal point, Unit: º
0038 30057
int
Lining
S.V.
Metric system: No decimal point, Unit: m/s
English system: No decimal point, Unit: ft/s
003A
30059 int
Lining incidence angle
1 places after decimal point, Unit: º
003C 30061
int
Fluid
S.V.
Metric system: No decimal point, Unit: m/s
English system: No decimal point, Unit: ft/s
003E
30063 int
Water incidence angle
1 place after decimal point, Unit: º
0040
30065 int
Propagation time (T0 C)
No decimal point, Unit:
Ps
0042
30067 int
Window open (Win C)
No decimal point, Unit:
Ps
0044
30069 long
Positive direction time (T1)
3 place after decimal point, Unit:
Ps
0048
30073 long
Backward direction time (T2)
3 place after decimal point, Unit:
Ps
004C
30077 long
Propagation time (T0)
3 place after decimal point, Unit:
Ps
0050
30081 long
Propagation time difference (DT)
4 place after decimal point, Unit: ns
0054 30085
long Delay
time
(Ta)
3 place after decimal point, Unit:
Ps
0058 30089
long Water incidence angle (
Tf)
3 place after decimal point, Unit: º
005C
30093 long
Fluid S.V. (Cf)
Metric system: 1 places after decimal point,
Unit: m/s
English system: 1 places after decimal point,
Unit: ft/s
0060
30097 long
Reynolds number (Re)
No decimal point
0064 30101
long
Flow profile compensation factor
(K)
4 places after decimal point
0068
30105 long
Mean velocity (V)
Metric system: 3 places after decimal point,
Unit: m/s
English system: 3 places after decimal point,
Unit: ft/s
006C
30109 int
U: Signal strength (AGC U)
2 places after decimal point, 0.00 to 100.00%
006E
30111 int
D: Signal strength (AGC D)
2 places after decimal point, 0.00 to 100.00%
0070 30113
unsigned
int
U: Maximum signal value (P/H U)
No decimal point
0072 30115
unsigned
int
D: Maximum signal value (P/H D)
No decimal point
0074
30117 int
U: Trigger level (TRG U)
2 places after decimal point, 0.00 to 100.00%
0076
30119 int
D: Trigger level (TRG D)
2 places after decimal point, 0.00 to 100.00%
0078 30121
long
U: Maximum signal value (after
filter)
No decimal point
007C 30125
long
D: Maximum signal value (after
filter)
No decimal point
0080
30129 long
Sensor spacing 1
Metric system: 2 places after decimal point,
Unit: mm
English system: 3 places after decimal point,
Unit: inch
Bulletin F-107-UXF3-S