7.2.3

Word data [Read-out only]: Function code [04H]

Relative

address

Register

No.

Data

type

Parameter

Read-out data/Write-in data setting range

Remarks

3XXXX

0000 30001

float Velocity

Metric system: 32-bit floating data, Unit: m/s
English system: 32-bit floating data, Unit: ft/s

0004

30005 float

Flow rate

32-bit floating data

Unit: Flow rate

0008

30009 float

Flow rate %

32-bit floating data, Unit: %

000C

30013 double

+ Total value

64-bit floating data

Unit: Total

0014 30021

double

Total value

64-bit floating data

001C

30029 long

+ Total pulse

No decimal point, Unit: Pulse

0020 30033

long

Total pulse

No decimal point, Unit: Pulse

0024 30037

unsigned
int

RAS information

Data of hexadecimal number

0026 30039

int

Not

use

0028 30041

int

Not

use

002A 30043

int

Not

use

002C 30045

int

Not

use

002E 30047

int

Not

use

0030 30049

int

Wedge

S.V.

Metric system: No decimal point, Unit: m/s
English system: No decimal point, Unit: ft/s

0032

30051 int

Wedge incidence angle

1 place after decimal point, Unit: º

0034 30053

int

Pipe

S.V.

Metric system: No decimal point, Unit: m/s
English system: No decimal point, Unit: ft/s

0036

30055 int

Pipe incidence angle

1 place after decimal point, Unit: º

0038 30057

int

Lining

S.V.

Metric system: No decimal point, Unit: m/s
English system: No decimal point, Unit: ft/s

003A

30059 int

Lining incidence angle

1 places after decimal point, Unit: º

003C 30061

int

Fluid

S.V.

Metric system: No decimal point, Unit: m/s
English system: No decimal point, Unit: ft/s

003E

30063 int

Water incidence angle

1 place after decimal point, Unit: º

0040

30065 int

Propagation time (T0 C)

No decimal point, Unit:

Ps

0042

30067 int

Window open (Win C)

No decimal point, Unit:

Ps

0044

30069 long

Positive direction time (T1)

3 place after decimal point, Unit:

Ps

0048

30073 long

Backward direction time (T2)

3 place after decimal point, Unit:

Ps

004C

30077 long

Propagation time (T0)

3 place after decimal point, Unit:

Ps

0050

30081 long

Propagation time difference (DT)

4 place after decimal point, Unit: ns

0054 30085

long Delay

time

(Ta)

3 place after decimal point, Unit:

Ps

0058 30089

long Water incidence angle (

Tf)

3 place after decimal point, Unit: º

005C

30093 long

Fluid S.V. (Cf)

Metric system: 1 places after decimal point,

Unit: m/s

English system: 1 places after decimal point,

Unit: ft/s

0060

30097 long

Reynolds number (Re)

No decimal point

0064 30101

long

Flow profile compensation factor
(K)

4 places after decimal point

0068

30105 long

Mean velocity (V)

Metric system: 3 places after decimal point,

Unit: m/s

English system: 3 places after decimal point,

Unit: ft/s

006C

30109 int

U: Signal strength (AGC U)

2 places after decimal point, 0.00 to 100.00%

006E

30111 int

D: Signal strength (AGC D)

2 places after decimal point, 0.00 to 100.00%

0070 30113

unsigned
int

U: Maximum signal value (P/H U)

No decimal point

0072 30115

unsigned
int

D: Maximum signal value (P/H D)

No decimal point

0074

30117 int

U: Trigger level (TRG U)

2 places after decimal point, 0.00 to 100.00%

0076

30119 int

D: Trigger level (TRG D)

2 places after decimal point, 0.00 to 100.00%

0078 30121

long

U: Maximum signal value (after
filter)

No decimal point

007C 30125

long

D: Maximum signal value (after
filter)

No decimal point

0080

30129 long

Sensor spacing 1

Metric system: 2 places after decimal point,

Unit: mm

English system: 3 places after decimal point,

Unit: inch

Bulletin F-107-UXF3-S