:TIMebase:MODe {MAIN | WINDow | SPLIT | XY | ?}

Parameter

MAIN

Sets the time base mode to main
screen.

WINDow

Sets the time base mode to zoom
window.

SPLIT

Sets the time base mode to split
screen. The split windows opening
numbers are depended on the
channels turned on numbers.
For example, if CH1 & CH4 turned
on, press the “SPLIT WINDOW” key
will open two split windows; if CH1,
CH2, CH4 turned on, four split
windows will be appeared on the
screen.

XY

Sets the time base mode to XY
display.

Return parameter

Returns the time base mode (MAIN, WINDOW,
SPLIT, XY)

Example

:TIMebase:MODe SPLIT

Sets the time base mode to split- screen mode.

:TIMebase:WINDow:POSition

Set

Query

Description

Sets or queries the zoom horizontal position.

Syntax

:TIMebase:WINDow:POSition { | ?}

Parameter

Horizontal position for zoom window

Return parameter

Returns the zoom horizontal position as

Example

:TIMebase:WINDow:POSition 2.0E-3