COMMAND DETAILS

61

:MEASure:FREQuency

Query

Description

Returns the frequency value.

Syntax

:MEASure:FREQuency{?}

Return parameter Returns the frequency as .

Note

Before using this command, select the
measurement channel. See the example below.

Example

:MEASure:SOURce1 CH1
:MEASure:FREQuency?
1.0E+3
Selects Channel 1, and then measures the
frequency.

:MEASure:NWIDth

Query

Description

Returns the first negative pulse width timing.

Syntax

:MEASure:NWIDth{?}

Return parameter Returns the negative pulse width as

Note

Before using this command, select the
measurement channel. See the example below.

Example

:MEASure:SOURce1 CH 1
:MEASure:NWIDth?
Selects Channel 1, and then measures the negative
pulse width.

:MEASure:PDUTy

Query

Description

Returns the positive duty cycle ratio as percentage.

Syntax

:MEASure:PDUTy{?}

Return parameter