6. Automation Software
The frame formats exchanged with the automation software through the serial port for each of the
emulated receivers are as follows:
6.1. Frame formats
a) Sur-gard Format
MLR2000
•
5RRLLLs18AAAAQXYZGGCCC[T]
Where:
RR: Receiver number
LLL: Line number
s: Space
18: Contact-Id format identifier
AAAA: Four-digit account code
Q: Qualificator, E= New event or opening; R=Restoration or closing; P=Previous event.
XYZ: Type of event and code for this
GG: Number or group or partition.
CCC: Zone number or user identifier.
[T]: 14 hex character as terminator
•
Heartbeat
1RR000sssssssssss@ssss[T]
Where:
RR: Receiver number
s: Space
@: Supervision character
[T]: 14 hex character as terminator
MLR2D
•
5RRLs18AAAAQXYZGGCCC
Where:
RR: Receiver number
L: Line number
s: Space
18: Contact-Id format identifier
AAAA: Four-digit account code
Q: Qualificator, E= New event or opening; R=Restoration or closing; P=Previous event.
XYZ: Type of event and code for this
GG: Number or group or partition.
CCC: Zone number or user identifier.
[T]: 14 hex character as terminator