beautypg.com

SilentKnight VisorAlarm Plus 2U User Manual

Page 37

background image

VISOR ALARM – Configuration

III - 35

Doc.DM374-I

Ver.1.0

To configure each of the parameters, use this syntax:

PRIMARY ARLY-1 Cfg>cfg-pattern 5 option value

The available options are all the mIP/IPDACT configuration parameters. These are detailed below.
Some of the parameters the mIP/IPDACT uses with the main VisorALARM PLUS 2U, others with the
backup device and others affect the maintenance VisorALARM PLUS 2U. The rest are common
application.

default: Creates a New pattern or sets the default values for an existing one.

instalator-password: Establishes the installer password. This must be following by a string

of up to 16 hexadecimal digits.

receiver-ip: VisorALARM PLUS 2U public address (or behind which the VisorALARM

PLUS 2U is located). This must be followed by an IP address.

receiver-udp-port: UDP port where the VisorALARM PLUS 2U expects to receive the data.

This must be followed by a number from 1 to 65535.

usr-password: mIP/IPDACT console password. Must be followed by a 16-character string

made up of hexadecimal digits or the letters UVWXYZ. The password sent to the
mIP/IPDACT will be a string of 16 hexadecimal digits which is obtained by substituting the
first digit of the mIP/IPDACT account number for the letter U, the V for the second and so
on until Z for the sixth. I.e. if you configure 0000UVWXYZ, when you install the
mIP/IPDACT whose account number is 123456, 0000123456 is sent as the user password.
This way you can configure different passwords for each mIP/IPDACT using the same
configuration pattern.

mip-password: Password used by the mIP/IPDACT to encrypt the messages it sends. This

must be followed by a password using the same form as the usr-password parameter.

receiver-password: Password used by the VisorALARM PLUS 2U to encrypt the messages

it sends. This must be followed by a password using the same format as the usr-password
parameter.

keep-alive-timer: Time between keepalives in seconds. This value must be between 0 and

90 seconds. Applied to the main VisorALARM PLUS 2U.

keep-alive-retries: Number of keepalive retries in cases of failure. This value must be

between 1 and 9. Applied to the main VisorALARM PLUS 2U.

keep-alive-retries-timer: Time between keepalive retries in seconds. This value must be

between 3 and 9 seconds. Applied to the main VisorALARM PLUS 2U.

phone-length: Number of digits making up the telephone number called by the panel to send

alarms.

alarm-tx-retries: Number of alarm send retries in cases of failure. This is a number between

5 and 10.

callback-phone

1

: Phone number that Alarm Panel dials to make a callback to the Central

Station.

bck-receiver-ip: Backup VisorALARM PLUS 2U IP address.

bck-keep-alive-timer: This is the same keep-alive-timer option applied to the backup

VisorALARM PLUS 2U.

bck-keep-alive-retries: This is the same keep-alive-retries option applied to the backup

VisorALARM PLUS 2U.

1

Not available in US versions