Brocade FastIron Ethernet Switch Software Upgrade Guide User Manual

Page 79

background image

show command output differences between 07.4.00 and 08.0.xx

show ip

bgp debug

network

1.2.3.0

255.255.25

5.0

Brocade#show ip bgp debug network 1.1.1.32/32

BGP: network 1.1.1.32/32 found

(x26ce0498, 0, 26ce0405) 1.1.1.32/32

weight:32768 back_door:0 imported:1

route-map:<> sptr:x0

next_hop:0.0.0.0 med:0 tag:0 type:1

Found entry is
added in front of
network.

show ipv6

ospf

memory

Brocade#sh ipv6 ospf memory

Total Dynamic Memory Allocated for this instance : 7944947 bytes

Memory Type Size Allocated Max-alloc Alloc-

Fails

MTYPE_OSPF6_AREA 471191 3 4 0

MTYPE_OSPF6_AREA_RANGE 29 0 4 0

MTYPE_OSPF6_SUMMARY_ADDRE 25 0 4 0

MTYPE_OSPF6_IF 280 254 256 0

MTYPE_OSPF6_NEIGHBOR 12502 3 8 0

MTYPE_OSPF6_ROUTE_NODE 21 324 512 0

MTYPE_OSPF6_ROUTE_INFO 35 322 512 0

MTYPE_OSPF6_PREFIX 20 0 4 0

MTYPE_OSPF6_LSA 129 976 1024 0

MTYPE_OSPF6_VERTEX 166 14 16 0

MTYPE_OSPF6_SPFTREE 44 3 4 0

MTYPE_OSPF6_NEXTHOP 28 258 512 0

MTYPE_OSPF6_EXTERNAL_INFO 40 2 512 0

MTYPE_THREAD 32 75 1024 0

MTYPE_OSPF6_LINK_LIST 20 15544 16384 0

MTYPE_OSPF6_LINK_NODE 12 2885 4096 0

MTYPE_OSPF6_LSA_RETRANSMI 6 0 1024 0

global memory pool for all instances

Memory Type Size Allocated Max-alloc Alloc-

Fails

MTYPE_OSPF6_TOP 61475 1 1 0

MTYPE_OSPF6_LSA_HDR 5072 976 977 0

MTYPE_OSPF6_RMAP_COMPILED 0 0 0 0

MTYPE_OSPF6_OTHER 0 0 0 0

MTYPE_THREAD_MASTER 84 1 1 0

Global Memory
pool for all
instances is
added.

show ip

ssh config

Brocade#show ip ssh config

SSH server : Enabled

SSH port : tcp\22

Host Key : DSA 1024

Encryption : AES-256, AES-192, AES-128, 3-DES

Permit empty password : No

Authentication methods : Password, Public-key, Interactive

Authentication retries : 3

Login timeout (seconds) : 120

Idle timeout (minutes) : 0

Strict management VRF : Disabled

SCP : Enabled

SSH IPv4 clients : All

SSH IPv6 clients : All

SSH IPv4 access-group :

SSH IPv6 access-group :

SSH Client Keys :

Brocade#

The output is
modified and now
it also shows Host
Key, Strict
management VRF,
and SSH Client
Keys.

FastIron Ethernet Switch Software Upgrade Guide
53-1003089-01