1.
Determine the current boot image version using the show flash command
Brocade#show flash
Active Management Module (Slot 9):
Compressed Pri Code size = 3613675, Version 03.1.00aT3e3 (sxr03100a.bin)
Compressed Sec Code size = 2250218, Version 03.1.00aT3e1 (sxs03100a.bin)
Compressed BootROM Code size = 524288, Version 03.0.01T3e5
Code Flash Free Space = 9699328
2.
Determine the current flash image version using the show version command.
device#show version
Copyright (c) 1996-2012 Brocade Communications Systems, Inc. All rights reserved.
UNIT 1: compiled on Mar 2 2012 at 12:38:17 labeled as ICX64S07400
(10360844 bytes) from Primary ICX64S07400.bin
SW: Version 07.4.00T311
Boot-Monitor Image size = 774980, Version:07.4.00T310 (kxz07400)
HW: Stackable ICX6450-24
3.
Determine the current license installed using the show version command.
device#show version
...
License: BASE_SOFT_PACKAGE (LID: dbuFJJHiFFi)
P-ENGINE 0: type DEF0, rev 01
...
4.
upgrading to a different type of image that uses a different license from the one which is already
on the device, generate a separate license file. For more information on license, see the FastIron
Ethernet Switch Administration Guide .
5.
exact list of software image files available for FastIron Release 08.0.xx, see the release notes.
Sample output - determining the software versions
Example for determining the flash image version
Enter the show version command at any level of the CLI. The following shows an example output:
device#show version
Copyright (c) 1996-2012 Brocade Communications Systems, Inc. All rights reserved.
UNIT 1: compiled on Mar 2 2012 at 12:38:17 labeled as ICX64S07400
(10360844 bytes) from Primary ICX64S07400.bin
SW: Version 07.4.00T311
Boot-Monitor Image size = 774980, Version:07.4.00T310 (kxz07400)
HW: Stackable ICX6450-24
==========================================================================
UNIT 1: SL 1: ICX6450-24 24-port Management Module
Serial #: BZSXXXXXXXX
License: BASE_SOFT_PACKAGE (LID: dbuFJJHiFFi)
P-ENGINE 0: type DEF0, rev 01
==========================================================================
UNIT 1: SL 2: ICX6450-SFP-Plus 4port 40G Module
==========================================================================
800 MHz ARM processor ARMv5TE, 400 MHz bus
65536 KB flash memory