App index basic setting commands – Yokogawa Button Operated MV2000 User Manual
Page 78
4-5
M-4662
Commands
1
2
3
4
5
6
7
App
Index
Basic Setting Commands
• To activate the settings that are changed with the basic setting commands, you must
save the settings with the YE or XE command. Make sure to save the settings before
changing from Basic Setting Mode to Operation Mode. Otherwise, new settings will
not take effect.
• The settings that are returned in response to a query in Basic Setting Mode will
contain the new settings even if they are not saved. However, the new settings will
not take effect until they are saved. To activate the new settings, you must save the
settings with the YE or XE command as described earlier. If you clear the settings
or change the execution mode from Basic Setting Mode to Operation Mode without
saving the settings, the MV will return the original settings in response to a query.
Note
• The settings that are changed with the YA, YK, RU, YQ, YS, YB, YD, WS, and WW commands
are activated after saving the new settings with the XE command and then power-cycling
the MV.
• Executing the YE or LO command will disconnect communications.
Group/Command
Name
Function
Execution Mode Administrator
User
See
Page
Setting
WO
Sets alarm and DO settings
Basic Setting Mode Yes
No
4-28
WH
Sets an alarm hysteresis
Basic Setting Mode Yes
No
4-28
XV
Sets the scan interval
Basic Setting Mode Yes
No
4-28
XB
Sets the burnout detection
Basic Setting Mode Yes
No
4-28
XJ
Sets an RJC
Basic Setting Mode Yes
No
4-29
WU
Sets environment settings
Basic Setting Mode Yes
No
4-29
XM
Sets the memory sample condition
Basic Setting Mode Yes
No
4-31
RF
Sets the key lock function
Basic Setting Mode Yes
No
4-31
RN
Sets basic login settings
Basic Setting Mode Yes
No
4-31
RP
Sets login and user limitations
Basic Setting Mode Yes
No
4-31
RO
Sets report types and generation times
Basic Setting Mode Yes
No
4-32
RM
Sets a report channel
Basic Setting Mode Yes
No
4-32
XG
Sets the time zone
Basic Setting Mode Yes
No
4-32
XN
Sets the date format
Basic Setting Mode Yes
No
4-33
YB
Sets host information
Basic Setting Mode Yes
No
4-33
YD
Sets network settings
Basic Setting Mode Yes
No
4-33
YA
Sets the IP address, subnet mask, and default
gateway
Basic Setting Mode Yes
No
4-33
YK
Sets the keepalive feature
Basic Setting Mode Yes
No
4-33
RU
Sets DNS parameters
Basic Setting Mode Yes
No
4-33
WS
Sets a server
Basic Setting Mode Yes
No
4-33
WW
Sets the Web homepage
Basic Setting Mode Yes
No
4-34
YQ
Sets the application timeout
Basic Setting Mode Yes
No
4-34
YT
Sets the FTP transfer timing
Basic Setting Mode Yes
No
4-34
YU
Sets the contents to be sent via e-mail
Basic Setting Mode Yes
No
4-34
YV
Sets e-mail recipient addresses
Basic Setting Mode Yes
No
4-35
YW
Sets the e-mail sender address
Basic Setting Mode Yes
No
4-35
YX
Sets the e-mail SNTP server name
Basic Setting Mode Yes
No
4-35
YJ
Sets a Modbus client destination server
Basic Setting Mode Yes
No
4-35
YP
Sets basic Modbus client settings
Basic Setting Mode Yes
No
4-36
YR
Sets a Modbus client transmission command
Basic Setting Mode Yes
No
4-36
WB
Sets SNTP client settings
Basic Setting Mode Yes
No
4-36
WC
Sets the SNTP operation when memory start is
executed
Basic Setting Mode Yes
No
4-36
YS
Sets serial interface parameters
Basic Setting Mode Yes
No
4-37
4.2 A List of Commands