beautypg.com

App index basic setting commands – Yokogawa Button Operated MV2000 User Manual

Page 78

background image

4-5

M-4662

Commands

1

2

3

4

5

6

7

App

Index

Basic Setting Commands

• To activate the settings that are changed with the basic setting commands, you must

save the settings with the YE or XE command. Make sure to save the settings before
changing from Basic Setting Mode to Operation Mode. Otherwise, new settings will
not take effect.

• The settings that are returned in response to a query in Basic Setting Mode will

contain the new settings even if they are not saved. However, the new settings will
not take effect until they are saved. To activate the new settings, you must save the
settings with the YE or XE command as described earlier. If you clear the settings
or change the execution mode from Basic Setting Mode to Operation Mode without
saving the settings, the MV will return the original settings in response to a query.

Note

• The settings that are changed with the YA, YK, RU, YQ, YS, YB, YD, WS, and WW commands

are activated after saving the new settings with the XE command and then power-cycling
the MV.

• Executing the YE or LO command will disconnect communications.

Group/Command
Name

Function

Execution Mode Administrator

User

See
Page

Setting
WO

Sets alarm and DO settings

Basic Setting Mode Yes

No

4-28

WH

Sets an alarm hysteresis

Basic Setting Mode Yes

No

4-28

XV

Sets the scan interval

Basic Setting Mode Yes

No

4-28

XB

Sets the burnout detection

Basic Setting Mode Yes

No

4-28

XJ

Sets an RJC

Basic Setting Mode Yes

No

4-29

WU

Sets environment settings

Basic Setting Mode Yes

No

4-29

XM

Sets the memory sample condition

Basic Setting Mode Yes

No

4-31

RF

Sets the key lock function

Basic Setting Mode Yes

No

4-31

RN

Sets basic login settings

Basic Setting Mode Yes

No

4-31

RP

Sets login and user limitations

Basic Setting Mode Yes

No

4-31

RO

Sets report types and generation times

Basic Setting Mode Yes

No

4-32

RM

Sets a report channel

Basic Setting Mode Yes

No

4-32

XG

Sets the time zone

Basic Setting Mode Yes

No

4-32

XN

Sets the date format

Basic Setting Mode Yes

No

4-33

YB

Sets host information

Basic Setting Mode Yes

No

4-33

YD

Sets network settings

Basic Setting Mode Yes

No

4-33

YA

Sets the IP address, subnet mask, and default
gateway

Basic Setting Mode Yes

No

4-33

YK

Sets the keepalive feature

Basic Setting Mode Yes

No

4-33

RU

Sets DNS parameters

Basic Setting Mode Yes

No

4-33

WS

Sets a server

Basic Setting Mode Yes

No

4-33

WW

Sets the Web homepage

Basic Setting Mode Yes

No

4-34

YQ

Sets the application timeout

Basic Setting Mode Yes

No

4-34

YT

Sets the FTP transfer timing

Basic Setting Mode Yes

No

4-34

YU

Sets the contents to be sent via e-mail

Basic Setting Mode Yes

No

4-34

YV

Sets e-mail recipient addresses

Basic Setting Mode Yes

No

4-35

YW

Sets the e-mail sender address

Basic Setting Mode Yes

No

4-35

YX

Sets the e-mail SNTP server name

Basic Setting Mode Yes

No

4-35

YJ

Sets a Modbus client destination server

Basic Setting Mode Yes

No

4-35

YP

Sets basic Modbus client settings

Basic Setting Mode Yes

No

4-36

YR

Sets a Modbus client transmission command

Basic Setting Mode Yes

No

4-36

WB

Sets SNTP client settings

Basic Setting Mode Yes

No

4-36

WC

Sets the SNTP operation when memory start is
executed

Basic Setting Mode Yes

No

4-36

YS

Sets serial interface parameters

Basic Setting Mode Yes

No

4-37

4.2 A List of Commands

This manual is related to the following products: