2 serial interface specifications, Rs-232 specifications – Yokogawa Button Operated MV2000 User Manual
Page 155
7-2
M-4662
7.2
Serial Interface Specifications
RS-232 Specifications
Connector type:
D-Sub 9-pin plug
Electrical and mechanical specifications:
Conforms to the EIA-574 standard (for the 9-pin interface of
the EIA-232 (RS-232) standard)
Connection:
Point-to-point
Transmission mode: Half-duplex
Synchronization:
Start-stop synchronization
Baud rate:
Select 1200, 2400, 4800, 9600, 19200, or 38400 [bps].
Start bit:
1 (fixed)
Data length:
Select 7 or 8 bits (To output data in BINARY format, be sure to
set the data length to 8 bits.)
Parity:
Select odd, even, or none
Stop bit:
1 (fixed)
Hardware handshaking: Select whether to fix the RS and CS signals to TRUE or to use
them for flow control.
Software handshaking: Select whether to use the X-ON and X-OFF signals to control
only the transmitted data or both the transmitted and received
data.
X-ON (ASCII 11H), X-OFF (ASCII 13H)
Receive buffer size:
2047 bytes
RS-422/485 Specifications
Terminal block type: 6 terminals, terminal screws: ISO M4/nominal length 6 mm
Electrical and mechanical specifications:
Conforms to EIA-422 (RS-422) and EIA-485 (RS-485)
standards
Connection:
Multidrop
Four-wire type
1:32
Two-wire type
1:31
Transmission mode: Half-duplex
Synchronization:
Start-stop synchronization
Baud rate:
Select 1200, 2400, 4800, 9600, 19200, or 38400 [bps].
Start bit:
1 (fixed)
Data length:
Select 7 or 8 bits
Parity:
Select odd, even, or none
Stop bit:
1 (fixed)
Receive buffer size:
2047 bytes
Escape sequence:
Open and close
Electrical characteristics: FG, SG, SDB, SDA, RDB, and RDA (six terminals)
SG, SDB, SDA, RDB, and RDA terminals are functionally
isolated from the MV internal circuit.
The FG terminal is frame ground.
Communication distance: Up to 1.2 km
Terminator:
External: recommended resistance 120 Ω, 1/2 W