Yokogawa Button Operated MV2000 User Manual
Page 141
5-23
M-4662
Responses
1
2
3
4
5
6
7
App
Index
Ethernet Information
• The MV returns the Ethernet information in response to an FA command.
• Syntax
EACRLF
IP_Address______:xxx.xxx.xxx.xxxCRLF
Subnet_mask_____:xxx.xxx.xxx.xxxCRLF
Default_Gateway_:xxx.xxx.xxx.xxxCRLF
Primary_DNS_____:xxx.xxx.xxx.xxxCRLF
Secondary_DNS___:xxx.xxx.xxx.xxxCRLF
Host____________:yyy······CRLF
Domain__________:zzz······CRLF
ENCRLF
xxx
IP address number (000 to 255)
yyy···
Host name (up to 64 characters)
zzz···
Domain name (up to 64 characters)
File List
• The MV returns the file list or the file data sizes for the specified directory on the MV’s
external storage medium in response to the ME command.
• Syntax
EACRLF
yy/mo/dd_hh:mm:ss_ssssssss_fff···_0_xxx···CRLF
··············································
ENCRLF
yy
Year (00 to 99)
mo
Month (01 to 12)
dd
Day (01 to 31)
hh
Hour (00 to 23)
mm
Minute (00 to 59)
ss
Second (00 to 59)
ssssssssss
Data size of the file (_______0 to 99999999) [byte(s)]
fff···
File name (51 characters including the extension. If it is less than
51, spaces are entered.)
If this is a directory, the characters
position displaying the file data size.
xxx···
Data serial number (16-digit hexadecimal)
_
Space
The data serial number is included for files in the DATA directory in the internal
memory. For other files, the data serial number is spaces.
5.2 Text Data Output Format