Yokogawa Button Operated MV2000 User Manual
Page 103
4-30
M-4662
To set computation settings
Syntax
WU p1,p2,p3,p4
p1
Setting type (MATH)
p2
Display on error
+OVER
-OVER
p3
Data when the SUM or AVE value overflows
ERROR
Set the computed result to
computation error
SKIP
Discard the data that overflowed
and continue the computation
LIMIT
Process the data as follows:
• High or low limit value in
the measurement range for
measurement channels that do
not use linear scaling
• High or low limit value in the
scaled range for measurement
channels that use linear scaling
• High or low limit value
in the specified span for
measurement channels
p4
Data when the MAX, MIN, or P-P value
overflows
OVER
Compute using the overflow data
SKIP
Discard the data that overflowed
and continue the computation
To set report settings
Syntax
WU p1,p2,p3,p4
p1
Setting type (REPORT)
p2
Report computation type 1
MAX
Maximum value
MIN
Minimum value
AVE
Average value
SUM
Sum value
INST
Instantaneous value
p3
Report computation type 2
OFF
Disable report computation
MAX
Maximum value
MIN
Minimum value
AVE
Average value
SUM
Sum value
INST
Instantaneous value
p4
Report computation type 3
Same as p3.
p5
Report computation type 4
Same as p3.
p6
Generation of “hourly+daily,” “daily+weekly,”
and “daily+monthly” files
COMBINE
Output to a single file.
SEPARATE
Output to separate files.
For parameters p2 to p5, the same computation
type cannot be specified except for OFF.
Auto service port
Syntax
WU p1,p2,p3,p4,p5
p1
Setting type (SERVICEPORT)
p2
FTP service port (1 to 65535)
p3
Web service port (1 to 65535)
p4
SNTP service port (1 to 65535)
p5
Modbus service port (1 to 65535)
Query
WU[ p1]?
To set the decimal type
Syntax
WU p1,p2
p1
Setting type (DECIMALPOINT
p2
Decimal type
POINT
Set the decimal to a period
COMMA
Set the decimal to a comma
Query
WU[p1]?
Example
Set the decimal to a comma.
WU DECIMALPOINT,COMMA
Description • The specified decimal type is applied to the
following items.
Items That the Decimal Type Setting Applies To
Item
Detailed Items
File output
Display data file
Event data file
Manual sample file
Report data file
Display
Trend display (digital display, scale
display)
Digital display
Bar graph display
Overview
Historical display (digital display, scale
display)
4 panel display
Report display
Web screen
All channel information display
Instantaneous data
Report data
• The specified decimal type is not applied to
the following items.
Items That the Decimal Type Setting Does Not Apply
To
Item
Detailed Items
File output
Setup file
Setup display
Span, scale, and alarm settings for
measured, computed, and external
input channels
Computation constant
Hysteresis value (fixed decimal place)
Communication
(setup/output)
Command and response syntax for
communication commands
• The decimal for items that the decimal type
setting does not apply to is displayed with a
period.
To set POP3 parameters
Syntax
WU p1,p2,p3
p1
Setting type (POP3)
p2
Number of seconds until sending e-mail to
the SMTP server (0 to 10)
p3
POP3 login method
PLAIN
Plain password
APOP
APOP password
4.6 Basic Setting Commands