7 output commands (control), App index – Yokogawa Button Operated MV2000 User Manual
Page 112
4-39
Commands
M-4662
1
2
3
4
5
6
7
App
Index
YE
Activates Basic Setting Mode
(cold reset)
Syntax
YE p1
p1
Setting activation
STORE
Start by saving the basic settings
ABORT
Start without saving basic settings
Example
Start by saving the basic settings.
YESTORE
4.7 Output Commands
(Control)
BO
Sets the byte output order
Syntax
BO p1
p1
Byte order
0
Transmits the data MSB first.
1
Transmits the data LSB first.
Query
BO?
Example
Output the data MSB first.
BO0
Description This command applies to the byte order of
numeric data for BINARY output.
CS
Sets the checksum
Syntax
CS p1
p1
Checksum usage
0
Not calculate (value fixed to zero)
1
Calculate
Query
CS?
Example
Enable (calculate) the checksum.
CS1
Description You can only use this command for serial
communications.
IF
Sets the status filter
Syntax
IF p1,P2
p1
Filter value of status information 1 to 4
(0.0.0.0 to 255.255.255.255)
p2
Filter value of status information 5 to 8
(0.0.0.0 to 255.255.255.255)
Query
IF?
Example
Set the status filter value to 1.0.4.0 and
255.127.63.31.
IF 1.0.4.0,255.127.63.31
Description See chapter 6 for details.
CC
Disconnects the Ethernet
connection
Syntax
CC p1
p1
Disconnection (0)
Example
Disconnect the connection.
CC0
4.6 Basic Setting Commands/4.7 Output Commands (Control)