beautypg.com

Yokogawa Button Operated DX2000 User Manual

Page 331

background image

13-13

IM 04L42B01-01E

Specifications

1

2

3

4

5

6

7

8

9

10

11

12

13

App

Index

Cu10, Cu25 RTD Input/3 Leg Isolated RTD Input (/N1)

Item

Specifications

Function

In addition to the standard input, the DX can also receive Cu10 and Cu25 input.
On the DX2010, DX2020, DX2030, DX2040, and DX2048, all the RTD input terminals (A, B,

and b) are isolated on each channel.

Measurement/display accuracy

Under standard operating conditions

Input Type

Measurement

Range

Setting

Accuracy

Guaranteed

Range

Measurement Accuracy

Max.

Resolution

A/D integration time:

16.7 ms or more

A/D integration time:

1.67 ms

Cu10 (GE)
Cu10 (L&N)
Cu10 (WEED)
Cu10 (BAILEY)
Cu10:α=0.00392 at 20°C
Cu10:α=0.00393 at 20°C
Cu25:α=0.00425 at 0°C

Cu1
Cu2
Cu3
Cu4
Cu5
Cu6
Cu25

–70.0 to 170.0°C
–75.0 to 150.0°C
–200.0 to 260.0°C

–200.0 to 300.0°C

–200.0 to 300.0°C

* Measuring current i = 1 mA

±(0.4% of rdg + 1.0°C)

±(0.3% of rdg + 0.8°C)

±(0.8% of rdg + 5.0°C)

±(0.5% of rdg + 2.0°C)

0.1°C

Input source resistance

1 Ω or less per wire (The resistance of all three wires must be equal).

Ambient temperature influence (applies when the A/D integration time is 16.67 ms or greater, with temperature variation of 10°C)

±(0.2% of range + 2 digits) or less

Input source resistance

With variation of 1 Ω per wire (resistance of all three wires must be equal): ±(0.1% of rdg + 1

digit) or less
With maximum difference of 40 mΩ between wires: Approx. 1°C

13.5 Options

This manual is related to the following products: