beautypg.com

Match time, Setup items • logic box number, Event-action > event – Yokogawa Button Operated DX2000 User Manual

Page 248

background image

7-2

IM 04L42B01-01E

• Match Time

Press

MENU (to switch to setting mode), and select the Menu tab > Timer, Event

action > Match time timer.

Setup Items

• Logic box number

You can set up to 40.

• Event-Action > Event

The condition to execute the action.

Settings

Description

None

Not use.

Remote

Select the remote control input terminal number.

Relay

Select the alarm output relay number. During Edge operation, a change from

deactivated to activated is an event.

Relay-Off

*2

Select the alarm output relay number. During Edge operation, a change from

activated to deactivated is an event. During Level operation, the action states

that correspond to “activated” and “deactivated” are the opposite of when you

select “Relay.”

Switch

Select the internal switch number. During Edge operation, a change from off to

on is an event.

Switch-Off

*2

Select the internal switch number. During Edge operation, a change from on to

off is an event. During Level operation, the action states that correspond to “on”

and “off” are the opposite of when you select “Switch.”

Timer

Select the timer number.

Matchtime

Select the match timer number.

Alarm

During Edge operation, a change from “no alarms are active” to “at least one

alarm is active” is an event.

Alarm-Off

*2

During Edge operation, a change from “at least one alarm is active” to “no

alarms are active” is an event. During Level operation, the action states that

correspond to “at least one alarm is active” and “no alarms are active” are the

opposite of when you select “Alarm.”

UserKey

-

Edge

*1

Select the event switch number (1 to 30). This function is available for release

numbers 3 and later.

Level

*1

Select the event switch number (1 to 30). During Edge operation, a change

from off to on is an event.

LevelOff

*2

Select the event switch number (1 to 30). During Edge operation, a change

from on to off is an event. During Level operation, the action states that

correspond to “on” and “off” are the opposite of when you set the event to

“Level.”

*1 Available for release numbers 3 and later.
*2 Available for release numbers 4 and later.

7.1 Setting the Event Action Function

(Including the remote control function of the /R1 and /PM1 options and the USER key)

This manual is related to the following products: