Explanation

• ALL CHANNEL

*

/GROUP CHANNEL on the Trend Display

In the group display, the waveforms of the channels that are registered to the group

are displayed. In all channel display, the waveforms of all channels that are configured
to record data are displayed on the current group display. The waveforms of channels
that are not assigned to the group are displayed in the waveform display area, but the
scales, current value marks, and digital values of the channels are not displayed.

* On a DX2010, DX2020, DX2030, DX2040, or DX2048 that is equipped with external input

channels (/MC1 option), all channel display is not possible when the trend update rate is 30
s/div or less.

• SCALE ON/OFF and DIGITAL ON/OFF on the Trend Display

Select whether to show or hide the scale and numeric display sections.

• AUTO SCROLL ON/OFF

The displayed groups can be automatically switched at a specified interval by

selecting

AUTO SCROLL ON. The display switches in ascending group order.

For the procedure to set the auto scroll interval of groups, see section 5.14.

• MESSAGE DISP 1 and MESSAGE DISP 2 on the Trend Display

Switches the message display method.

• AUTO ZONE (Release number 3 or later)

Displays trend waveforms separately by evenly dividing display areas (zones) among

a group’s channels.

With AUTO ZONE OFF

With AUTO ZONE ON

Waveform display area

is divided evenly.

• FINE GRID (Release number 3 or later)

Display the fine grid when the normal grid is too wide for reading measured values.

The fine grid can be used in the trend and historical trend displays. The fine grid
places an additional four lines between the normal grid lines.

With FINE GRID OFF

With FINE GRID ON

Fine grid

4.2 Displaying the Measured Data as Waveforms, Values, or Bar Graphs