Yokogawa Button Operated DX2000 User Manual
Page 250
7-4
IM 04L42B01-01E
• Timer
Timer used by event action. Used also in the TLOG computation computation function.
* The timer cannot be changed while memory sampling or computation is in progress.
• Timer No.
Up to four timers (1 to 4) can be set.
When Using an Absolute Timer
• Mode
Select
Absolute.
• Interval
Select the interval from the available settings between 1min to 24h.
• Ref.time
Set the time in the range of hour 0 to hour 23.
When Using a Relative Timer
• Mode
Select
Relative.
• Interval
Set the interval in the range of 00:01 (1 min) to 24:00 (24 hours).
• Reset at Math Start
On: Resets the timer when computation is started. The resetting of the timer is not
considered to be a timeout. Even if the timer is used as an event, the action is not
executed.
• Match Time Timer
Set the time match condition used in event action.
* The condition cannot be changed while memory sampling or computation is in progress.
• Timer number
You can set up to four match time conditions (1 to 4).
• Kind
Settings
Description
Day
Set the time match condition of a day.
Week
Set the time match condition of a week.
Month
Set the time match condition of a month.
Year
The condition is matched once a year. This function is available for
release numbers 3 and later.
Set the items with check marks in the following table depending on the Kind setting.
Day
Week
Month
Year
Day
Day of week
Hour:Minute
Type
Setting
Month
• Month
Set the month.
• Day
Set the day.
• Weekday
Set the day of the week.
• Hour:Minute
Set the time in the range of 00:00 to 23:59.
• Timer action
Settings
Description
Single
Executes the action once when the condition is met.
Repeat
Executes the action at every specified time.
7.1 Setting the Event Action Function
(Including the remote control function of the /R1 and /PM1 options and the USER key)