Dtm (hart 5) menu tree, Operation via hart configuration tool (hart 5) – Yokogawa digitalYEWFLO (DY) User Manual
Page 72

<8. OPERATION VIA HART CONFIGURATION TOOL (HART 5)>
8-12
IM 01F06A00-01EN
• DTM (HART 5) Menu Tree
A
B
C
D
E
F
G
F0812.ai
3URFHVVYDULDEOHV
'HYLFHVWDWXV
'LDJDQG6HUYLFH
(DV\VHWXS
&RQILJXUDWLRQ
&DOLEUDWLRQ
:ULWH3URWHFW
5RRW0HQX'70
F0813.ai
Process Variables
PV
PV % rng
AO1
Flow span
PV damp
Total
Temp
TV % rnge
AO3
Temp 0%
Temp 100%
Temp damping
(R)
(R)
(R)
(R)
(R)
(R)
(R)
(R)
(R)
(R)
(R)
(R)
(M)
(M)
(M)
(RW)
(M)
[A20]
[A10]
[B10]
[B15]
[A30]
[A41]
[A40]
[B51]
[B52]
[F50]
[J40]
(MV)
(MV)
(MV)
(MV)
(MV)
(MV)
A
Easy Setup
Tag
Contact output
Contact output
Pulse rate
Freq at 100%
Setting level
Flow span
Analog out select
Analog out select
Temp 0%
Temp 100%
PV Damp
Temp damping
Total rate
Upper display
Lower display
(RW)
(R)
(M)
(R)
(R)
(R)
(RW)
(R)
(M)
(R)
(R)
(RW)
(RW)
(RW)
(RW)
(RW)
[B20]
[B21]
[B22]
[B23]
[B10]
[B50]
[B51]
[B52]
[B15]
[F50]
[B45]
[B30]
[B31]
(MV)
(MV)
(MV)
D
Device Status
Process Variables
Diagnostic List
PV
PV % rnge
TV % rnge
Temp
Device Status
Status group1
Status group2
Status group3
[A20]
[A10]
[A41]
[A40]
(R)
(R)
(R)
(R)
(R)
(R) Status group 1 enum
(R) Status group 2 enum
(R) Status group 3 enum
(MV)
(MV)
(MV)
B
Diag and Service
Loop test
Loop test pulse/status
Amplifier check
Test auto release time
Master reset
Error Record
Er record status 1
Er record status 2
Er record status 3
(R) Er record group 1 enum
(R) Status group 2 enum
(R) Status group 3 enum
C
Parameter No. in display and BRAIN Terminal
Upload/Download
Device revision 4.0 or later
Read only
Continuous read
Read and Write
Method of HCF
Unique Method of DY
Only for Multi-Variable Type
(R)
(CR)
(RW)
(M)
(MV)
[ ]
*
F0814.ai
Configuration
Meter
Flow Setting
Special Units
Total
Adjust
Maintenance
Analog Output
Device information
HART
(MV)
(MV)
(MV)
(MV)
(MV)
[E10]
[E20]
[E30]
[E40]
[E41]
[E50]
[F52]
[B30]
[B31]
[D40]
[D41]
[D42]
[D43]
[A30]
[B40]
[B45]
[H20]
[H25]
[K36]
[H30]
[H40]
[D20]
[K10]
[K20]
[K25]
[K26]
[K45]
[K30]
[K32]
[K34]
[K36]
[B10]
[B15]
[D30]
[B50]
[F50]
(RW)
(RW)
(RW)
(RW)
(RW)
(RW)
(RW)
(RW)
(RW)
(R)
(R)
(M)
(R)
(M)
(R)
(M)
(R)
(R)
(R)
(R)
(RW)
(RW)
(M)
(RW)
(R)
(M)
(R)
(RW)
(R)
(M)
(RW)
(RW)
(RW)
(R)
(M)
(R)
(RW)
(R)
(R)
(R)
(R)
(RW)
(RW)
(RW)
(R)
(RW)
(R)
(M)
(RW)
(R)
(R)
(R)
(R)
(RW)
(RW)
(RW)
(RW)
(RW)
(RW)
(R)
(R)
(R)
(R)
(M)
(R)
(R)
(RW) Burst mode enum
(RW) Burst option enum
Nominal size
Body type
Sensor type
K-factor unit
K-factor
Detector No
Cable length
Upper display
Lower display
Sensor status
Function
Function
Fluid
Fluid
Indicate parameter depends on
the choice in 'Fluid/Function'.
Special unit
Special unit
Base unit
User's unit
Conversion factor
Total
Total start/stop
Total rate
Total reset
User adjust
Raynolds adjust
Raynolds adjust
Process density
Gas expansion fact
Flow adjust
Flow adjust
Indicate parameter only when
'Flow adjust' is activated.
Lowcut
TLA
Signal level
Noise balance mode
Noise balance mode
Noise ratio
High vibration
Velocity
Span Velocity
Vortex frequency
Span frequency
Menu type number
Flow span
PV Damp
AO Arlm typ
Out limit(H)
Analog out select
Analog out select
Temp damping
Model
Manufacturer
Hardware rev
Software rev
Descriptor
Massage
Date
Final asmbly num
Tag
Poll addr
Dev id
Universal rev
Fld dev rev
Next universal rev
Chng universal rev
Num req preams
Physical signl code
Burst mode
Burst option
E
Calibration
D/A trim
Scaled D/A trim
F
Write Protect
write protect
Software seal
(M)
(M)
(M)
(R)
G