5 self-diagnostic (error code list), Self-diagnostic (error code list) -20, Parameters – Yokogawa digitalYEWFLO (DY) User Manual
Page 56

<6. PARAMETERS>
6-20
IM 01F06A00-01EN
Indication
Diagnostic
Message
Error Name
Problem Cause
Current Output
% Output
Pulse
Output
Engineering
Unit Output
Totalizing
Output
Engineering
Temp Output
Pulse / Status Output
How to recover
Select
fl ow
rate
Select
temperature
Select
fl ow
rate
Select
temperature
Pulse
(*2)
Status
(*2)
Alarm
(*2)
Err-01
FLOW
OVER
OUTPUT
Over range
output
signal
Output signal is
110% or more
(*1)
Fixed at
110%
(*1)
Normal
Operation
Fixed at
110%
(*1)
Normal
Operation
Normal
Operation
Normal
Operation
Normal
Operation
Normal
Operation
Normal
Operation
Normal
Operation
OFF(H)
Change
parameters or
over ranged
fl ow
input
Err-02
SP
AN
SET
ERROR
Span Setting
Error
Span setting
parameter is more
than 1.5 times of
max
fl ow
velocity
Normal
Operation
Normal
Operation
Normal
Operation
Normal
Operation
Normal
Operation
Normal
Operation
Normal
Operation
Normal
Operation
Normal
Operation
Normal
Operation
OFF(H)
Change
parameters span
factor is outside the
acceptable limits
Err-06
PULSE
OUT
ERROR
Pulse output
error
Pulse output
frequency is more
than 10kHz
Normal
Operation
Normal
Operation
Normal
Operation
Normal
Operation
Fixed at
10KHz
Normal
Operation
Normal
Operation
Normal
Operation
Fixed at
10kHz
Change
parameters
(ItemC,ItemE)
Err-07
PULSE
SET
ERROR
Pulse setting
error
Pulse output
frequency setting is
more than 10kHz
Normal
Operation
Normal
Operation
Normal
Operation
Normal
Operation
Normal
Operation
Normal
Operation
Normal
Operation
Normal
Operation
Normal
Operation
Change
parameters
(ItemC,ItemE)
CHECK
V
ibration
T
ransient
noise
Error of
V
ibration
T
ransitional
disturbance
Hold
Normal
Operation
Hold
Normal
Operation
Normal
Operation
Hold
Normal
Operation
Normal
Operation
Hold
Hold
OFF(H)
CHECK
the
vibration
CHECK
V
ibration
High
vibration
Error of
V
ibration
High vibration
Based on
K45
Normal
Operation
Based on
K45
Normal
Operation
Stop Output
Based on
K45
Stop the total
Normal
Operation
Normal
Operation
Normal
Operation
OFF(H)
CHECK
the
vibration
CHECK
Flow
Fluctualing
Error of Flow
Fluctuating
Normal
Operation
Normal
Operation
Normal
Operation
Normal
Operation
Normal
Operation
Normal
Operation
Normal
Operation
Normal
Operation
Normal
Operation
Normal
Operation
OFF(H)
CHECK
the
clogging
CHECK
Flow
Clogging
Error of Flow
Clogging
Normal
Operation
Normal
Operation
Normal
Operation
Normal
Operation
Normal
Operation
Normal
Operation
Normal
Operation
Normal
Operation
Normal
Operation
Normal
Operation
OFF(H)
CHECK
the
clogging
Err-10
(*3)
TEMP
OVER
OUTPUT
Over range
Temp output
signal
Temp output signal
is 1
10% or more,
and 0% below
.
Normal
Operation
Fixed at 1
10%
in case of over
110%, and
fi xed
at 0% when
in case of less
than 0%.
(*1)
Normal
Operation
Fixed at 1
10%
in case of over
110%, and
fi xed
at 0% when in
case of less than
0%.
(*1)
Normal
Operation
Normal
Operation
Normal
Operation
Normal
Operation
Normal
Operation
Normal
Operation
OFF(H)
CHECK
the
temperature
or temperature
span
Err-1
1
(*3)
OVER
TEMP
Error of
temperature
Temp value is -50°C
below or 300°C
over
.
Remain in
operationat
Temp=-50°C or
Temp=300°C
Remain in
operation at
Temp=-50°C or
Temp=300°C
Remain in
operationat
Temp=-50°C or
Temp=300°C
Remain in
operation at
Temp=-50°C or
Temp=300°C
Remain in
operation at
Temp=-50°C or
Temp=300°C
Remain in
operation at
Temp=-50°C or
Temp=300°C
Remain in
operation at
Temp=-50°C or
Temp=300°C
Remain in
operation at
Temp=-50°C or
Temp=300°C
Remain in
operation at
Temp=-50°C or
Temp=300°C
Remain in
operation at
Temp=-50°C or
Temp=300°C
OFF(H)
CHECK
the
temperature
Err-12
(*3)
TEMP
SENSOR
FAUL
T
Error of
thermometer
Disconnection
or short of
thermometer sensor
Remain in
operation
at Manual
setting
condition
Based on F58
Remain in
operation
at Manual
setting
condition
Based on F58
Remain in
operation
at Manual
setting
condition
Remain in
operation
at Manual
setting
condition
Remain in
operation
at Manual
setting
condition
Based on
F58
Remain in
operation
at Manual
setting
condition
Remain in
operation
at Manual
setting
condition
OFF(H)
Change
thermometer
sensor
.
Err-13
(*3)
TEMP
CONV
.
FAUL
T
Error of
temperature
converter
Temperature
converter is failed
Remain in
operation
at Manual
setting
condition
Based on F58
Remain in
operation
at Manual
setting
condition
Based on F58
Remain in
operation
at Manual
setting
condition
Remain in
operation
at Manual
setting
condition
Remain in
operation
at Manual
setting
condition
Based on
F58
Remain in
operation
at Manual
setting
condition
Remain in
operation
at Manual
setting
condition
OFF(H)
Change
converter
case build in
temperature
sensor
.
Err-20
PRE-AMP
ERROR
PRE-AMP
is
failed
Normal
Operation
Remain in
operation at
Manual Setting
Temperature
Value
Normal
Operation
Remain in
operation at
Manual Setting
Temperature
V
alue
Normal
Operation
Normal
Operation
Normal
Operation
Remain in
operation at
Manual Setting
Temperature
Value
Normal
Operation
Normal
Operation
OFF(H)
Replace
the
AMP
. unit
Err-30
EE
PROM
ERROR
EEPROM
is not
functioning
correctly
Over 1
10%
or -2.5%
below
Over 1
10% or
-2.5% below
Fixed at 0%
Fixed at 0%
Halt
Fixed at 0%
Halt
Fixed at 0%
Stop the
Output
OFF(H)
OFF(H)
Replace
the
AMP
. unit
Err-40
FLOW
SEBSOR
FAUL
T
Error of Flow
sensor
Flow sensor Is fauit.
Normal
Operation
Normal
Operation
Normal
Operation
Normal
Operation
Normal
Operation
Normal
Operation
Normal
Operation
Normal
Operation
Normal
Operation
Normal
Operation
OFF(H)
Change
Flow
sensor
CPU F
AUL
T
CPU is
failed
All operations are
Dead. Display and
self dignostic function
is also dead.g
Over 1
10%
or -2.5%
below
Over 1
10% or
-2.5% below
Halt
Halt
Halt
Halt
Halt
Halt
Halt
Halt
Halt
Replace
the
AMP
. unit
Note. Normal Operation : Operation continues without relation to error occurrence.
Remain in Operation : Calculation continues with relation to error occurrence.
(*1): “1
10%” is based on “D30 : OUT
LIMIT(H)”.
(*2):
Pulse output
: These conditions should be done in case of which B20 is “SCALED PULSE”, “UNSCALED PULSE”, “FREQUENCY”.
Status output :
These conditions should be done in case of which B20 is “FLOW SW (LOW :ON)”, “FLOW SW (LOW : OFF)”.
Alarm output
: These conditions should be done in case of which B20 is “Alarm”.
(*3): Only for /MV
6.5 Self-Diagnostic (Error Code List)
When an ERROR is displayed by SELF CHECK in item A60, B60, C60, D60, E60, H60, J60, K60 or M60,
press function key F2 [DIAG] and the error contents are displayed.