beautypg.com

Ransburg, Amplifier, Rcs-2 user manual - appendix – Ransburg RCS 2 Ratio Control System User Manual

Page 70

background image

APPENDIX J: MOTOR AMPLIFIER LED DISPLAY FAULT CODES

(PART 2) (Continued)

AMPLIFIER

Status LED

Blink Code

Fault Description

Explanation and/or Possible Causes

15

16

17

18

19

20

SFD Sensor Failure

SFD UART Error

SFD Communication Error

Option Card Watch Dog

Time Out

Position Error Too Large

Option Card Fault

Internal SFD failure.

Excessive electrical noise in the drive environment

causing communications interference.

Internal SFD failure.

Feedback cable not connected at the drive or at the

motor.

Feedback cable shield not connected.

Defective feedback cable.

Internal SFD failure.

Excessive electrical noise in the drive environment

causing communications interference.

Communication error between option card and main board.

Check

ExtFaults:

ExtFaults = Step size over flow means

GearOut/GearIn is too large.

ExtFaults = Position error over flow means that the

following error,

= PosErr, has exceeded ±128 revs.

Check if the motor is stalling or if the commanded speed is

higher than the motor can achieve at the present bus voltage.

Check

ExtFaults:

If

ExtFaults is AuxFBFault, then the AusFB device is in error.

Check the AuxFB faults: AuxFBEnDatFlt, AuxFBPTCFit, or

AuxFBSCDFlt.

Check to make sure the the drive is set up for the correct

feedback device and that the device is functioning

correctly. If

ExtFaults is "No Extended Fault", then this was a

fault induced by the controller, such as SynqLost.

RCS-2 User Manual - Appendix

67

LN-9407-00.2

Ransburg