6. If the spraygun tips start to become plugged or

some other restriction occurs, causing the actual

flow to fall significantly below the targeted flow rate,

the operators can again trigger both handguns,

push and hold the feather set pushbutton (until

the target flow rate is achieved) then release the

feather set pushbutton, and a new (higher) feather

set pressure will be recorded.

Once again, the master channel feather pressure

PID parameters may have to be adjusted to control

how fast the pumps respond to a change in flow.

This directly effects how close to the target feather

pressure the actual outlet pressure is maintained.