beautypg.com

Ransburg – Ransburg RCS 2 Ratio Control System User Manual

Page 27

background image

independent of each other. Note that the horn must

be enabled on the CONFIG SYSTEM screen or

the horn will not sound for gun faults regardless

of whether or not they are configured to do so on

the CONFIG GUN screens.

System Pulse

Type of Output: System

Type of Signal: Pulsing

This output pulses at approximately a 0.5 hertz rate

as long as the processor on the interface board

does not detect any on-board firmware problems.

Users may wish to use this signal to detect when

the RCS-2 controller is powered up and running.

System User Link

Type of Output: System

Type of Signal: Maintained

This output is energized as long as the Ethernet

link between the user interface PC and the inter-

face card is functioning.

NOTES

RCS-2 User Manual - Installation

24

LN-9407-00.2

Ransburg