beautypg.com

Ransburg, Amplifier, Rcs-2 user manual - appendix – Ransburg RCS 2 Ratio Control System User Manual

Page 69

background image

APPENDIX J: MOTOR AMPLIFIER LED DISPLAY FAULT CODES

(PART 2) (Continued)

AMPLIFIER

Fault Description

Explanation and/or Possible Causes

7

8

9

10

11

12

13

14

Bus Over Voltage - Self Resetting

The BUS voltage has exceeded

the upper threshold limit

Bus Under Voltage - Self Resetting

S200 DC drive fault only

BUS voltage is below specified

20 VDC minimum

Motor I-I or I-n Short

Line-to-Line, Line-to-Neutral, or

Line-to-PE short on the motor

ouput causing an instataneous

over current

Output Over Current

Hall Fault

Valid only when drive is set to 6

Step (Hall feedback) operation

SFD Configuration Error

J3 FB +5V Short

Excessive current drain on SFD

+5 supply output

SFD Motor Data Error

Motor data in SFD is outside

drive limits or is inconsistent

AC Line voltage (AC unit) or DC bus power supply

voltage (DC unit) is too high.

Regenative energy during deceleration is cusing the

BUS to rise:

On AC Drives add regen resistor.

On S200 DC input drives external BUS capacitor is too

small; add capacitance.

On S200 DC input drives:

BUS voltage is too low.

BUS voltage is pulled down during high acceleration or

loading.

External BUS capacitor is too small.

Motor power wiring short circuit - line-to-ground/neutral.

Motor cable short line-to-line.

Motor power cable length exceeds the data sheet

specification causing excessive motor line-to-earth

ground/neutral capacitance.

Internal motor winding short circuit.

Motor L too small.

KIP set too large.

Insufficient motor inductance

KIP or KII improperly set causing excessive output

current overshoots.

Invalid configuration.

Motor overspeed.

Invalid hall state.

Invalid hall transition.

SFD UART error during SFD initialization.

Bad motor data check sum.

The drive will attempt to initialize the SFD up to 4 times.

If it fails, this error is reported.

Excessive loading on SFD +5 supply.

Short in the feedback cable on SFD +5 (J3-1) to ground.

Motor and Drive are not compatible. Auto setup calcula-

tion yielded a desired parameter value outside valid range.

Incorrect/inconsistent motor data loaded into the SFD.

Status LED

Blink Code

RCS-2 User Manual - Appendix

66

LN-9407-00.2

Ransburg