Ransburg, General description, Specifications – Ransburg RCS 2 Ratio Control System User Manual
Page 10: Main control console, Rcs-2 user manual - introduction
Size:
Stand Alone Cart Mount Version:
71" High x 28" Wide x 32" Deep
(180.34 cm X 71.12 cm X 81.28 cm)
Main Control Console:
24" High x 24" Wide x 17" Deep
(61 cm X 61 cm X 43.18 cm)
Motor Amplifier Panel:
24" High x 24" Wide x 13" Deep
(61 cm X 61 cm X 33 cm)
Fluid Panel:
34" High x 21" Wide x 24" Deep
(86.36 cm X 53.34 cm X 61 cm)
Weight:
400 lbs. (181.5 Kg)
Operating Temperature:
32°F to 120°F
(0°C to 49°C)
Operating Humidity: 0% to 95%
Power Requirements:
120 VAC at 10
Amps
(240 VAC at 5 Amps)
Pneumatic Air Consumption:
Less
than 5 cfm
Pneumatic Air Inlet Size:
3/8" ODT
Pneumatic Air Outlet Size: ¼” ODT
User Interface
Processor:
1 GHz Intel
®
PIII
Running
Windows
Embedded
XP
Interface Board Processor: Rabbit 2000™
Channel Board Processor:
Motorola MC68HC16
Fluid Capacity: 0.9 cc/min to 1500 cc/min
per pump
Fluid Inlet Size:
3/8" ODT
Fluid Viscosity Range: 20–1000 centipoise
Fluid Inlet Pressure: 0 psi to 200 psi
Fluid Outlet Pressure: 200 psi maximum
GENERAL DESCRIPTION
The
RCS-2 System is composed of four basic
elements:
• Main Control Console
• Motor Amplifier Panel
• Fluid Panel
• Remote Operator's Panel
The Main Control Console can control up to 8
pumps, the Motor Amplifier Panels will interface
with either one or two pumps, and the Fluid
Panels are available with either one or two
pumps.
Main Control Console
The Main Control Console is the heart of the
system. It houses the following items:
• User-interface computer
• Control card rack
• Ethernet switch
• Interface card
• Channel card(s)
• 15" color LCD touch screen display
• DC power supply
• Ribbon cable interface boards
• Power and I/O terminal strip
• Noise filter and fuses
• I/O connectors for motor amplifier panels
The
User Interface Computer is a Pentium
®
based PC with a non-volatile flash-disk that
contains a Windows XP
®
Embedded operating
system and the RCS-2 user-interface software.
It has an on-board Ethernet port to allow interface
with the interface card. The computer has USB
ports for updating its software and for backing-up
parameter data. Keyboard and mouse ports are
also available on the unit for setup, diagnostics,
and troubleshooting, if necessary.
The
control card rack is a half-width 19" rack
with space for one RIO card, one interface card,
and up to four channel cards. It is powered from
24 VDC and utilizes up to 9 ribbon cable con-
nections (if all 8 channels are used). High speed
communications between cards is accomplished
using a Motorola
®
SPI bus.
SPECIFICATIONS
RCS-2 User Manual - Introduction