beautypg.com

Ransburg, Rcs-2 user manual - operation – Ransburg RCS 2 Ratio Control System User Manual

Page 42

background image

Maximum Flow

The allowable range of values for this parameter

is any integer from 0 cc/min to 10,000 cc/min.

When using an analog input to control the target

flow rate, this is the flow rate that the controller will

try to maintain if the maximum voltage (10 VDC)

or current (20 mA) is applied to the analog input.

Minimum Flow

The allowable range of values for this parameter

is any integer from 0 cc/min to 10,000 cc/min.

When using an analog input to control the target

flow rate, this is the flow rate that the controller

will try to maintain if the minimum voltage (0 VDC)

or current (4 mA) is applied to the analog input.

Bar Graph Limit

The allowable range of values for this parameter

is any integer from 0 cc/min to 10,000 cc/min.

This is the flow rate indicated by top of the flow rate

bar-graphs on the Main Screen and determines

the maximum value displayed on the plot-graphs.

Pot-Life Timer

The allowable range of values for this parameter

is any integer from 0 min. to 1000 min. This is

the amount of time that mixed plural component

material is allowed to remain in the fluid stream

after being mixed before a flush-request output

and error is issued by the controller.

Feather Pressure

The allowable range of values for this parameter

is any integer value from 0 psi to 255 psi.

This value is the pressure that will be maintained

at the outlet of the pump (or pumps) when a gun

is configured as a manual mode gun and the op-

er-ator is feathering the spray gun. (See Appendix

H for more details on Feather Modes.)

Fill Volume

This is the amount of material that the user wish-

es to flow through the pump(s) when the gun is

placed in the volume fill mode.

The following 8 parameters have a master

channel component and a slave channel com-

ponent. (Note the master and slave columns on

the screen.) Both values must be programmed

for plural component materials.

Pressure Pot Capacity

The allowable range of values for this parameter

is any value from 0.000 liters to 255.000 liters.

This value is simply the volume of material that

the pressure pot will be filled with each time it is

refilled. There is a pot reset button on the Job

Totals screen (F9) that must be actuated every

time a pot is filled.

Delta Pressure

The allowable range of values for this parameter

is any integer value from 0 psi to 20 psi.

This is the target differential pressure that the

controller tries to maintain across the pump.

Keeping the differential pressure across the

pump to a minimum is essential, especially with

low-viscosity materials. If the outbound pressure

of the pump is significantly higher than the inbound

pressure and the pump has any significant wear,

it is possible for the gear teeth to “slip by” a small

volume of material and less material will be de-

livered per revolution of the pump. If the inbound

pressure is significantly higher than the outbound

pressure, then material can “blow by” the pump

and more material than desired will be delivered.

The pump should essentially act as a metering

device as opposed to a pumping device.

Minimum Inlet Fluid Pressure

The allowable range of values for this parameter

is any integer value from 0 psi to 200 psi.

This is the target pressure that the controller tries

to maintain on the inlet of the pump as long as

the minimum inlet control pressure setting is not

greater than this setting.

RCS-2 User Manual - Operation

39

LN-9407-00.2

Ransburg