beautypg.com

Ransburg, Channel fill, Feather set – Ransburg RCS 2 Ratio Control System User Manual

Page 22: Halt/fault reset, Trigger 1, Motor amp enable, Triggers 2, 3, and 4, Rcs-2 user manual - installation

background image

determines this based on the programmed pump

sizes and the programmed ratio. Pulsing the halt/

reset input takes the gun out of the fast fill mode.

Channel Fill

Type of Input: Channel

Type of Signal: Pulsed

A gun must be in the ready state to use this mode.

This mode functions the same for single channel

guns as it does for dual channel guns.

When this input is pulsed, the pump for that channel

is run at its maximum rate (150 RPM) until the halt

signal is pulsed. It is not necessary for the trigger

input to be energized. If it is desired to have both

channels of a two channel gun run at full speed

(for flushing, etc.) this input must be pulsed on

both channels. The halt signal for the specific

channel that is channel filling must be pulsed. For

example: if both channels are channel filling, both

halt signals must be pulsed to stop them.

Feather Set

Type of Input: Gun

Type of Signal: Pulsed

If the gun is configured as a manual mode gun and

the value zero (0) is programmed in for feather

pressure (under the CONFIG JOB parameters)

this input can be used to program the feather

pressure "on the fly". That is, if a handsprayer is

painting and this input is momentarily energized,

the RCS-2 controller takes a snapshot of the out-

bound pressure of the pumps (or the pressure at

the optional feather pressure sensor, if it is being

used) and then starts controlling the speed of the

pumps to maintain that pressure. The optional

Remote Operator’s Panel has a pushbutton on

it that allows the handsprayer to utilize this fea-

ture. (Refer to "Appendix H" for more details on

feathering.)

Run

Type of Input: Gun

Type of Signal: Pulsed

This signal takes a configured gun from the ready

state to the "run" mode. In order for a gun to spray,

it must first be put into run mode. It is essentially

a way of enabling a gun. Energizing the trigger

input of a gun will not cause fluid to flow unless

the gun has first been placed in run mode.

Halt/Fault Reset

Type of Input: Gun

Type of Signal: Pulsed

This input takes a configured gun that is in run

mode to the ready state, essentially disabling the

gun from spraying. It also resets a fault for the

gun if it is in the faulted state.

Trigger 1

Type of Input: Gun

Type of Signal: Maintained

This input tells the controller to run the pumps if and

only if the gun has first been placed in run mode.

Motor Amp Enable

Type of Input: Channel

Type of Signal: Maintained

This is an input to the controller from the motor

amplifier indicating that the motor amplifier has

been enabled by the channel card and that there

are no problems.

Triggers 2, 3, and 4

Type of Input: Gun

Type of Signal: Maintained

These signals are additional trigger input signals.

They would be used in cases where the output of

a fluid panel was split between multiple applica-

tors. They work in conjunction with the trigger 1

input to allow up to 4 independent triggers, one

for each of 4 applicators. The software can be

configured in such a way that if one of these inputs

is on, the fluid panel delivers the target flow rate

of material. If a second input is turned on, then

the fluid panel will deliver twice the target flow

rate. If a third input is energized, three times the

target flow is delivered and if all four inputs are

energized, the fluid panel will deliver four times the

target flow rate. It is assumed that each of these

inputs are also connected to the trigger inputs on

four independent applicators.

RCS-2 User Manual - Installation

19

LN-9407-00.2

Ransburg