background image

is used as the source for these inputs, it must be

referenced to the ground terminal (terminal #1113).

There are two types of discrete digital inputs,

pulsed inputs and maintained inputs. The pulsed

inputs must be turned on and held on for 250 mil-

liseconds minimum, to insure operation. Multiple

DISCRETE CHANNEL AND

GUN INPUTS

All discrete digital inputs are optically isolated and

will function with an input voltage in the range of

10 VDC to 45 VDC. Factory jumper settings on

the interface and channel boards require that

voltage be sourced to the discrete input. If, how-

ever, a sinking input is required, inputs can be

reconfigured by changing those jumpers. (See

Appendix C for Channel Board Jumper Settings.)

It is recommended that the 24 VDC power supply

in the controller be used to source these inputs

(terminal #1331). Optionally, if an external supply

Figure 10: Gun I-O Sourcing-Sinking

>

Times stated above are for discrete

digital inputs only. When interfacing us-

ing Bradley's Remot I/O (aka RIO), these

times may vary significantly. (Refer to the

RCS-2 RIO Interface Programmer's Man-

ual for more details.)

NOTE

pulsed signals to a gun should also be separated

by 250 milliseconds. For example, don't turn the

halt/reset signal off at the same time that the run

signal is being turned on as results will be unpre-

dictable. Maintained signals operate as long as

the input remains energized.

Some discrete digital inputs are specific to a gun

and others are specific for a channel. If it is a gun

input and the gun is configured as a two channel

gun, field wiring must always be connected to the

master channel terminals (channel A).

Fast Fill

Type of Input: Gun

Type of Signal: Pulsed

The gun must be in run mode prior to initiating

this mode or the RCS-2 controller will ignore it.

If the gun is configured at a two-channel gun, and

this input is pulsed, the gun will be placed in fast

fill mode. The pumps will run at the maximum

speed possible while maintaining the target ratio.

That is, the software will determine which of the

two pumps can be run at its maximum speed (150

RPM) and run the opposite channel at whatever

speed is necessary to ensure the proper ratio

of component A to component B. The software

If the gun is configured as a single channel gun

and this signal is pulsed, the gun will be put in

fast fill mode. This will cause the pump to run at

its maximum rate (150 RPM) until the halt signal

is pulsed. (It is not necessary to have the trigger

signal energized.)