Calibration menu, English – Burkert Type 8175 User Manual
Page 97

29
8175
ENGLISH
CALIBRATION MENU
4.4.1 Language
The selection of an alternative language is confirmed by the Enter-key and becomes imme-
diately active.
4.4.2 Engineering Units
ENTER
ENTER
0......9
The selection of the units will depend on the application and the configuration of the trans-
mitter via level, distance or volume for fluid measurement.
-
If the transmitter is to be configured to measure Level or Distance, select the measuring
units and decimal points as required.
-
If volume is to be selected and configured it is important to note that the transmitter
display within the ‘VOLUME TEACH-IN‘ may not be the measuring units selected.
The conversion of units by the transmitter only applies within the Volume Teach-In and
the table below displays the measuring units selected and the displayed units which will
be used within the Volume Teach-In.
UNIT
LANGUAGE
ENGLISH
DEUTSCH
FRANCAIS
ITALIANO
ESPANOL
Selected measuring units
Units used for Teach-In
Distance
Volume
Distance
Volume
cm
L
m
L
m
L
m
L
cm
m
3
m
m
3
m
m
3
m
m
3
cm
US/Imp Gal
Not to be used
m
US/Imp Gal
Not to be used
inch
L
Not to be used
foot
L
Not to be used
inch
m
3
ft
m
3
foot
m
3
ft
m
3
inch
US/Imp Gal
ft
US/Imp Gal
foot
US/Imp Gal
ft
US/Imp Gal