Adjustmentandcommissioning
Refer to chap. 8.9 to access Parameters menu.
Parameters
Functions
F1...F6:
Type:
VOL. DOSING
Name:
Status:
ENTERING
OFF
ON
CMD Safe:
Mode:
Value:
PV:
Unit:
This is
when the
device is be-
ing parame-
tered............
....................
This is
when the
device is be-
ing parame-
tered............
....................
OFF
ON
ENTERING
M0:MAIN
Mx:
DI1 Pulse
None
DI2 Pulse
DI1 Flow
DI2 Flow
None
DI1 Totalizer
DI2 Totalizer
m3
L
gal
Igal
Volume:
ENTERING
Dosing time:
ENTERING
TYPE: Indicates the function chosen.
NAME: Rename the function chosen. See chap. 8.4. This name appears in the view associated with this function
in Process level.
STATUS: Used to activate (choose "ON") or deactivate (choose "OFF") the function.
PV: Define the digital input "DI1" or "DI2" as the volume metering base.
UNIT: Choose the unit of volume.
VOLUME: Enter the volume to be metered.
DOSING TIME: Enter the duration of dosing.
CMD SAFE: Confirm (choose "Mode: ON") or do not confirm (choose "Mode:OFF") the use of a fallback position
on the output when the "System switch" event (see chap. 8.10.17) has the state "ON". When use of the fallback
position is confirmed, enter a fallback position value of between 0 and 100% for each output.
"volume"
"dosing time"
"volume"
"volume" = v1+v2+v3+v4+v5+v6
v1
v2 v3
v4
v5 v6
Figure 56 :
Example of the "volume dosing" function
Type 8619