Burkert Type 8619 User Manual
Page 30

28
Installationandwiring
Wire colour
signal
ME
RE
RE
GD
CG
FE
SE
TS
TS
1 2 3 4 5 6 7 8 9
translucid
white
green
grey
green/yellow
blue
red
strap (not
delivered)
black
(coax)
FE = functional earth
translucid
pH sensor
red (coax cable
shielding)
reference electrode
blue
rhodium electrode
green/yellow
cable shielding
grey
sensor body
green
Pt1000
white
Pt1000
Figure 15 :
Wiring a Bürkert 8201 type sensor with integrated Pt1000 temperature sensor in symmetrical mode using a
Variopin connection cable with order code 554856 or 554857
ME
RE
RE
GD
CG
FE
SE
TS
TS
1 2 3 4 5 6 7 8 9
Oxidation reduction potential
measurement electrode
Reference electrode
Temperature
sensor
Strap (not delivered)
FE = functional earth
Figure 16 :
Wiring an oxidation reduction potential sensor and a Pt100 or Pt1000 temperature sensor in a pH/ORP
module
ME
RE
RE
GD
CG
FE
SE
TS
TS
1 2 3 4 5 6 7 8 9
pH
measurement
electrode
Reference
electrode
Temperature
sensor
Oxidation reduction potential
measurement electrode
FE = functional earth
Figure 17 :
Wiring a pH sensor, an oxidation reduction potential sensor and a Pt100 or Pt1000 temperature sensor in a
pH/ORP module
Type 8619
english