ABUS AZ4299 Terxon SX Base Kit with sounder Installation User Manual

Page 131

background image

55

UK

27

Set 2
This output is activated for a definable
time period (command 170) if the alarm
centre is activated completely (A) or
internally (B), (C) or (D) (command
171).

28

Set 3
This output is activated for a definable
time period (command 170) if the alarm
centre is activated completely (A) or
internally (B), (C) or (D) (command
171).

29

Set 4
This output is activated for a definable
time period (command 170) if the alarm
centre is activated completely (A) or
internally (B), (C) or (D) (command
171).
The output is also activated if a fire or
panic alarm is triggered.

30

Unset 1
This output is activated for a definable
time period (command 170) if the alarm
centre is deactivated completely (A) or
internally (B), (C) or (D) (command
171).

31

Unset 2
This output is activated for a definable
time period (command 170) if the alarm
centre is deactivated completely (A) or
internally (B), (C) or (D) (command
171).

32

Unset 3
This output is activated for a definable
time period (command 170) if the alarm
centre is deactivated completely (A) or
internally (B), (C) or (D) (command
171).

33

Unset 4
This output is activated for a definable
time period (command 170) if the alarm
centre is deactivated completely (A) or
internally (B), (C) or (D) (command
171).

34

Fire
This output is activated if a fire alarm is
triggered. The output remains active
until the alarm is deactivated.

35

PA
This output is activated if a fire alarm is
triggered. The output remains active
until the alarm is deactivated.

4. Confirm your input. On the control unit, enter:

.

5. The control unit acknowledges your input with a

double “beep” tone and shows Installer Mode.

082 Transistor output OP2

To change the behaviour of transistor output OP2 on the
alarm centre PCB:

1. On the control unit, enter:

082

2. The LCD display shows: 082: Strobe

3. Via the keypad, select from the items described

above and enter the function accordingly:

083 Transistor output OP3

To change the behaviour of transistor output OP3 on the
alarm centre PCB:

1. On the control unit, enter:

083

2. The LCD display shows: 083: Set Latch

3. Via the keypad, select from the items described

above and enter the function accordingly:

085 Burglary output

To change the behaviour of the transistor output on
burglar alarms:

1. On the control unit, enter:

085

2. The LCD display shows: 085: Burg=Latched

3. Via the keypad, select from the following items

and press: