ABUS AZ4299 Terxon SX Base Kit with sounder Installation User Manual

Page 114

background image

38

UK

Duration of inactive pulse 1

(172

n

n

n

n

)

Menu item

Setting

Meaning

172

00 latched

output

01 – 12

Pulse duration in
seconds

Switch output inactive stable

(173

n

n

n

n

)

Menu item

Setting

Meaning

173

A B C D

Activate switch output
for inactive area

Switch output for fire

(174

n

n

n

n

)

Menu item

Setting

Meaning

174

0

Switch output off

1

Switch output on

Switch output for panic

(175

n

n

n

n

)

Menu item

Setting

Meaning

175

0

Switch output off

1

Switch output on

Last output for settling time

(182

n

)

Menu item

Setting

Meaning

182

07 7

seconds

08 8

seconds

09 9

seconds

10 10

seconds

11 11

seconds

12 12

seconds

Change display time (183

n

)

Menu item

Setting

Meaning

183

Max. 16
locations

C/D – left / right

Fire transmitter (184

n

)

Menu item

Setting

Meaning

184

0 OFF

1

ON

Auto reset key switch (185

n

)

Menu item

Setting

Meaning

185

0 OFF

1

ON

Display of zone resistance (199

)

Menu item

Setting

Meaning

199

Keys 1 + 3 zone selection


Entry delay group 1

(201

n

)

Menu item

Setting

Meaning

201

1 10

seconds

2

20

seconds

3

30

seconds

4

45

seconds

5

60

seconds

6

120

seconds

Entry delay group 2

(202

n

)

See 201

Entry delay group 3

(203

n

)

See 201

Entry delay group 4

(204

n

)

See 201

Software version (991

)