ABUS AZ4299 Terxon SX Base Kit with sounder Installation User Manual
Page 110

34
UK
Entry/exit delay volume
(045
n
)
Menu item
Setting
Meaning
045
0 No
signal
1…9
1 = quiet – 9 = loud
Tamper alarm reaction (046
n
)
Menu item
Setting
Meaning
046
0 Internal
alarm
1
Control
unit
2
Internal + control unit
Date and time (051
)
See also the description of how to enter date and time.
Menu item
Setting
Meaning
051
DnnMnnYnn
Enter date
HnnMnn
Enter time
Zone and tamper lock (052
n
)
See also the description of how to enter date and time.
Menu item
Setting
Meaning
052
0
Zone lock possible
1
Zone and tamper lock
possible
Cancel - Reset (053
n
)
Menu item
Setting
Meaning
053
0
Option as in item 33
1
Reset by user
Zone behaviour at Internal B (060
n
)
Menu item
Setting
Meaning
060
0
Entry/exit zone remains
entry/exit zone
1
Entry/exit zone becomes
immediate zone
Zone behaviour at Internal B (061
n
)
Menu item
Setting
Meaning
061
0 Following
entry
remains
following entry
1
Following entry becomes
entry/exit zone
Exit mode for Internal B (062
n
)
Menu item
Setting
Meaning
062
0
Exit time + quiet tone
1
Immediate
2
Silent
3
As exit mode for overall
activated
Alarm behaviour at Internal B (063
n
)
Menu item
Setting
Meaning
063
0
Only control unit
1
Loudspeaker and control
unit
2
Local
Alarm
3
External Alarm (siren and
dialler)
Exit time at Internal B (065
n
)
Menu item
Setting
Meaning
065
1 10
sec
2
20
sec
3
30
sec
4
45
sec
5
60
sec
6
120
sec
Zone behaviour at Internal C (070
n
)
Menu item
Setting
Meaning
070
0
Entry/exit zone remains
entry/exit zone
1
Entry/exit zone becomes
immediate zone
Zone behaviour at Internal C (071
n
)
Menu item
Setting
Meaning
071
0 Following
entry
remains
following entry
1
Following entry becomes
entry/exit zone