035 First alarm reaction
Proceed as follows to change the property of the first
alarm reaction:
1. On the control unit, enter:
035
2. The LCD display shows: 035:Lock-out ON
3. Via the keypad, select from the following items
and press:
0
Lock-out ON
When the alarm time expires (alarm
time of the local alarm of the external
siren), the alarm centre is reactivated.
The zone that triggered the alarm is no
longer monitored.
1
Re-arm
When the alarm time expires (alarm
time of the local alarm of the external
siren), the alarm centre is reactivated.
The zone that triggered the alarm is
monitored again.
4. Confirm your input. On the control unit, enter:
.
5. The control unit acknowledges your input with a
double “beep” tone and shows Installer mode.
038 System Sabotage Reset
To change the property of the System Sabotage Reset:
1. On the control unit, enter:
038
2. The LCD display shows: 038: EnSysTmp ON
3. Via the keypad, select from the following items
and press:
0
EnSysTmp OFF
In the event of a system sabotage, you
can reset the alarm centre by entering
the user code.
1
EnSysTmp ON
In the event of a system sabotage, you
can reset the alarm centre by entering
the installer code.
4. Confirm your input. On the control unit, enter:
.
5. The control unit acknowledges your input with a
double “beep” tone and shows Installer Mode.
039 Exit mode for overall activated (A)
To change the property of the exit mode for overall
activated:
1. On the control unit, enter:
039
2. The LCD display shows: 039: A=Timed
3. Via the keypad, select from the following items
and press:
0
A=Timed
After the alarm centre is activated, the
programmed exit delay time starts. At
the end of the delay time, the alarm
centre is activated. If zones are open at
this time, an alarm is triggered.
1
A=Terminated
After the alarm centre is activated, the
exit delay time starts. The delay time
runs until a button connected to a
control unit is pressed, which ends the
exit delay time manually. The exit delay
time ends seven seconds after the
button is pressed.
2
A=Final Door
After the alarm centre is activated, the
exit delay time starts. The delay time
runs until a zone with the entry/exit
property is closed. The exit delay time
ends seven seconds after the zone is
closed.
3
A=Lock Set
After the alarm centre is activated, the
delay time starts. The delay time runs
until a zone with the entry/exit property
is closed and, after the zone has
closed, a contact connected to the
control unit is opened.