beautypg.com

ABUS AZ4299 Terxon SX Base Kit with sounder Installation User Manual

Page 124

background image

48

UK

045 Entry/exit delay tone volume

To change the property of the entry/exit delay tone
volume:

1. On the control unit, enter:

045

2. The LCD display shows: 045:EE VOL=5

3. Via the keypad, select from the following items

and press:

0

EE VOL=OFF
Entry/exit delay tone off

1-9

EE Vol=1 / 2 / 3 / 4 / 5 / 6 / 7 / 8 / 9
Entry/exit delay tone quiet (1) to loud
(9)

4. Confirm your input. On the control unit, enter:

.

5. The control unit acknowledges your input with a

double “beep” tone and shows Installer Mode.

046 Tamper alarm

To change the property of the tamper alarm for a
deactivated alarm centre:

1. On the control unit, enter:

046

2. The LCD display shows: 046: Int+RKP

3. Via the keypad, select from the following items

and press:

0

Internal
Following a tamper alarm when the
alarm centre is deactivated, only the
intern alarm is triggered.

1

Keypad
Following a tamper alarm when the
alarm centre is deactivated, the control
unit is triggered.

2

Int+RKP
Following a tamper alarm when the
alarm centre is deactivated, the control
unit and the internal alarm are
triggered.

4. Confirm your input. On the control unit, enter:

.

5. The control unit acknowledges your input with a

double “beep” tone and shows Installer Mode.

051 Date and time

Proceed as follows to change the date and time:

1. On the control unit, enter:

051

2. The LCD display can show: 051: D03 M02 Y05

3. Via the keypad, select from the following items

and enter the date:

4. Confirm your input with

.

5. Enter the month via the keypad. (January to

September = 01 to 09)

6. Confirm your input with

.

7. Enter the year via the keypad.

8. Confirm your input with

.

9. The display changes; now enter the hour via the

keypad.

10. Confirm your input with

.

11. Enter the minute via the keypad.

12. Confirm your input with

.

13. The control unit acknowledges your input with a

double “beep” tone and shows Installer Mode.

052 Block tamper

Proceed as follows to change the property of the tamper
alarm:

1. On the control unit, enter:

052

2. The LCD display shows: 052:Omit Alarm

3. Via the keypad, select from the following items

and press:

0

Omit Alarm
You can only block some zones; a
tamper zone or a tamper alarm cannot
be blocked.