48
UK
045 Entry/exit delay tone volume
To change the property of the entry/exit delay tone
volume:
1. On the control unit, enter:
045
2. The LCD display shows: 045:EE VOL=5
3. Via the keypad, select from the following items
and press:
0
EE VOL=OFF
Entry/exit delay tone off
1-9
EE Vol=1 / 2 / 3 / 4 / 5 / 6 / 7 / 8 / 9
Entry/exit delay tone quiet (1) to loud
(9)
4. Confirm your input. On the control unit, enter:
.
5. The control unit acknowledges your input with a
double “beep” tone and shows Installer Mode.
046 Tamper alarm
To change the property of the tamper alarm for a
deactivated alarm centre:
1. On the control unit, enter:
046
2. The LCD display shows: 046: Int+RKP
3. Via the keypad, select from the following items
and press:
0
Internal
Following a tamper alarm when the
alarm centre is deactivated, only the
intern alarm is triggered.
1
Keypad
Following a tamper alarm when the
alarm centre is deactivated, the control
unit is triggered.
2
Int+RKP
Following a tamper alarm when the
alarm centre is deactivated, the control
unit and the internal alarm are
triggered.
4. Confirm your input. On the control unit, enter:
.
5. The control unit acknowledges your input with a
double “beep” tone and shows Installer Mode.
051 Date and time
Proceed as follows to change the date and time:
1. On the control unit, enter:
051
2. The LCD display can show: 051: D03 M02 Y05
3. Via the keypad, select from the following items
and enter the date:
4. Confirm your input with
.
5. Enter the month via the keypad. (January to
September = 01 to 09)
6. Confirm your input with
.
7. Enter the year via the keypad.
8. Confirm your input with
.
9. The display changes; now enter the hour via the
keypad.
10. Confirm your input with
.
11. Enter the minute via the keypad.
12. Confirm your input with
.
13. The control unit acknowledges your input with a
double “beep” tone and shows Installer Mode.
052 Block tamper
Proceed as follows to change the property of the tamper
alarm:
1. On the control unit, enter:
052
2. The LCD display shows: 052:Omit Alarm
3. Via the keypad, select from the following items
and press:
0
Omit Alarm
You can only block some zones; a
tamper zone or a tamper alarm cannot
be blocked.