ABUS AZ4299 Terxon SX Base Kit with sounder Installation User Manual

Page 126

background image

50

UK

062 Behaviour of exist mode internal active
(B)

To change the property of the exit mode for internal active
(B):

1. On the control unit, enter:

062

2. The LCD display shows: 062: B=LEISE

3. Via the keypad, select from the following items

and press:

0

Low Tone
The acoustic signal during the exit
delay time is emitted at half volume.

1

Instant
During internal activation, the alarm
centre is internally activated
immediately – i.e., without delay.

2

Silent
No acoustic signal is emitted during the
delay time. Following expiry of the delay
time, the alarm centre emits a brief
signal.

3

B=A
The initial mode for internal active B is
as for the initial mode of overall active A

4. Confirm your input. On the control unit, enter:

.

5. The control unit acknowledges your input with a

double “beep” tone and shows Installer Mode.

063 Alarm behaviour for internal active (B)

To change the alarm property for internal active (B):

1. On the control unit, enter:

063

2. The LCD display shows: 063: B=Keypad

3. Via the keypad, select from the following items

and press:

0

B=Keypad
Only the control units are activated.

1

B=Internal
On alarm, the control units and the
internal alarm are activated.

2

B=Local
On alarm, the control units, the internal
alarm and the external siren are
activated.

3

B=Full
On alarm, the control units, the internal
signalling, the external sirens and the
telephone dialler are activated.

4. Confirm your input. On the control unit, enter:

.

5. The control unit acknowledges your input with a

double “beep” tone and shows Installer Mode.

065 Exit delay time internal B

To change the property of the exit delay time for internal
active B:

1. On the control unit, enter:

065

2. The LCD display shows: 065: Exit B=20

3. Via the keypad, select from the following items

and press:

1

Exit B=10
Exit delay time for internal active B is 10
seconds.

2

Exit B=20
Exit delay time for internal active B is 20
seconds.

3

Exit B=30
Exit delay time for internal active B is 30
seconds.

4

Exit B=45
Exit delay time for internal active B is 45
seconds.

5

Exit B=60
Exit delay time for internal active B is 60
seconds.

6

Exit B=120
Exit delay time for internal active B is
120 seconds.

4. Confirm your input. On the control unit, enter:

.