6 register 4dhb_p2_prochot error status, 6 register 4dh, B_p2_prochot error status – Rainbow Electronics LM93 User Manual
Page 50: 0 registers
16.0 Registers
(Continued)
16.5.6 Register 4Dh
B_P2_PROCHOT Error Status
Register
Address
Read/
Write
Register
Name
Bit 7
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
Default
Value
4Dh
RWC
H_P2_PROCHOT
Error Status
PH2_ERR
TMAX
T100
T75
T50
T25
T12
T0
00h
Bit
Name
R/W
Description
Sleep
Masking
0
T0
RWC Set when P2_PROCHOT has had a throttled event. This bit is set for any
amount of PROCHOT throttling
>
0%.
S3, S4/5
1
T12
RWC Set when P2_PROCHOT has throttled greater than or equal to 0.00% but
less than 12.5%.
S3, S4/5
2
T25
RWC Set when P2_PROCHOT has throttled greater than or equal to 12.5% but
less than 25%.
S3, S4/5
3
T50
RWC Set when P2_PROCHOT has throttled greater than or equal to 25% but less
than 50%.
S3, S4/5
4
T75
RWC Set when P2_PROCHOT has throttled greater than or equal to 50% but less
than 75%.
S3, S4/5
5
T100
RWC Set when P2_PROCHOT has throttled greater than or equal to 75% but less
than 100%.
S3, S4/5
6
TMAX
RWC Set when P2_PROCHOT has throttled 100%.
S3, S4/5
7
PH2_ERR
RWC Set when P2_PROCHOT has throttled more than the user limit.
S3, S4/5
The PH2_ERR bit is the only bit in this register that will set HOST_ ERR in the LM93 Status/Control register.
LM93
www.national.com
50