0 registers – Rainbow Electronics LM93 User Manual
Page 36
16.0 Registers
(Continued)
Lock
Register Name
Address
Default
Description
LIMIT REGISTERS
Zone 2 (CPU2) High Temp
7Bh
80h
High limit for external thermal diode temperature channel 2
(D2) measurement
Zone 3 (Internal) Low Temp
7Ch
80h
Low limit for local temperature measurement
Zone 3 (Internal) High Temp
7Dh
80h
High limit for local temperature measurement
Zone 4 (External Digital) Low Temp
7Eh
80h
Low limit for external digital temperature sensor
Zone 4 (External Digital) High Temp
7Fh
80h
High limit for external digital temperature sensor
x
Fan Boost Temp Zone 1
80h
3Ch
Zone 1 (CPU1) fan boost temperature
x
Fan Boost Temp Zone 2
81h
3Ch
Zone 2 (CPU2) fan boost temperature
x
Fan Boost Temp Zone 3
82h
23h
Zone 3 (Internal) fan boost temperature
x
Fan Boost Temp Zone 4
83h
23h
Zone 4 (External Digital) fan boost temperature
Reserved
84h-8Fh
N/D
AD_IN1 Low Limit
90h
00h
Low limit for analog input 1 measurement
AD_IN1 High Limit
91h
FFh
High limit for analog input 1 measurement
AD_IN2 Low Limit
92h
00h
Low limit for analog input 2 measurement
AD_IN2 High Limit
93h
FFh
High limit for analog input 2 measurement
AD_IN3 Low Limit
94h
00h
Low limit for analog input 3 measurement
AD_IN3 High Limit
95h
FFh
High limit for analog input 3 measurement
AD_IN4 Low Limit
96h
00h
Low limit for analog input 4 measurement
AD_IN4 High Limit
97h
FFh
High limit for analog input 4 measurement
AD_IN5 Low Limit
98h
00h
Low limit for analog input 5 measurement
AD_IN5 High Limit
99h
FFh
High limit for analog input 5 measurement
AD_IN6 Low Limit
9Ah
00h
Low limit for analog input 6 measurement
AD_IN6 High Limit
9Bh
FFh
High limit for analog input 6 measurement
AD_IN7 Low Limit
9Ch
00h
Low limit for analog input 7 measurement
AD_IN7 High Limit
9Dh
FFh
High limit for analog input 7 measurement
AD_IN8 Low Limit
9Eh
00h
Low limit for analog input 8 measurement
AD_IN8 High Limit
9Fh
FFh
High limit for analog input 8 measurement
AD_IN9 Low Limit
A0h
00h
Low limit for analog input 9 measurement
AD_IN9 High Limit
A1h
FFh
High limit for analog input 9 measurement
AD_IN10 Low Limit
A2h
00h
Low limit for analog input 10 measurement
AD_IN10 High Limit
A3h
FFh
High limit for analog input 10 measurement
AD_IN11 Low Limit
A4h
00h
Low limit for analog input 11 measurement
AD_IN11 High Limit
A5h
FFh
High limit for analog input 11 measurement
AD_IN12 Low Limit
A6h
00h
Low limit for analog input 12 measurement
AD_IN12 High Limit
A7h
FFh
High limit for analog input 12 measurement
AD_IN13 Low Limit
A8h
00h
Low limit for analog input 13 measurement
AD_IN13 High Limit
A9h
FFh
High limit for analog input 13 measurement
AD_IN14 Low Limit
AAh
00h
Low limit for analog input 14 measurement
AD_IN14 High Limit
ABh
FFh
High limit for analog input 14 measurement
AD_IN15 Low Limit
ACh
00h
Low limit for analog input 15 measurement
AD_IN15 High Limit
ADh
FFh
High limit for analog input 15 measurement
AD_IN16 Low Limit
AEh
00h
Low limit for analog input 16 measurement
AD_IN16 High Limit
AFh
FFh
High limit for analog input 16 measurement
P1_PROCHOT User Limit
B0h
FFh
User settable limit for P1_PROCHOT
LM93
www.national.com
36