beautypg.com

Ds1876 sfp controller with dual ldd interface – Rainbow Electronics DS1876 User Manual

Page 55

background image

______________________________________________________________________________________ 55

DS1876

SFP Controller with Dual LDD Interface

Table 02h, Register B4h–B7h: PW2

Table 02h, Register B8h: RESERVED

Table 02h, Register B9h: HBIAS2 DAC

FACTORY DEFAULT

FFFF FFFFh

READ ACCESS

N/A

WRITE ACCESS

PW2

MEMORY TYPE

Nonvolatile (SEE)

B4h

2

31

2

30

2

29

2

28

2

27

2

26

2

25

2

24

B5h

2

23

2

22

2

21

2

20

2

19

2

18

2

17

2

16

B6h

2

15

2

14

2

13

2

12

2

11

2

10

2

9

2

8

B7h

2

7

2

6

2

5

2

4

2

3

2

2

2

1

2

0

BIT 7

BIT 0

The PWE value is compared against the value written to this location to enable PW2 access. At power-on, the
PWE value is set to all ones. Thus, writing these bytes to all ones grants PW2 access on power-on without writing
the password entry. All reads of this register are 00h.

FACTORY DEFAULT
READ ACCESS

N/A

WRITE ACCESS

N/A

A2h AND B2h MEMORY

N/A

MEMORY TYPE

N/A

This register is reserved.

FACTORY DEFAULT

00h

READ ACCESS

PW2 or (PW1 and RWTBL2) or (PW1 and RTBL2)

WRITE ACCESS

(PW2 and QT2EN = 0) or (PW1 and RWTBL2 and QT2EN = 0)

A2h AND B2h MEMORY

Common A2h and B2h memory location

MEMORY TYPE

Volatile

B9h

2

7

2

6

2

5

2

4

2

3

2

2

2

1

2

0

BIT 7

BIT 0

The digital value used for the HBIAS2 reference and recalled from Table 06h (Registers E0h–E7h) (transmitter 2) at
the adjusted memory address found in TINDEX. This register is updated at the end of the temperature conversion.
Comparisons greater than V

HBIAS2

compared against V

BMON2

create an HBAL alarm.

HBIAS2

Full Scale

V

HBIAS2 DAC

256

=

Ч