beautypg.com

Midi data format – Yamaha 006IPTO-F0 User Manual

Page 373

background image

MIDI Data Format

373

DM1000 Version 2—Owner’s Manual

Appendix

2.12.3.24 Parameter request

(Remote Meter)

Reception
This is received if [Parameter change RX] is ON and the [Rx CH] matches the
device number included in the SUB STATUS. This is echoed if [Parameter
change ECHO] is ON.
When this is received, data of the specified address is transmitted on the [Rx
CH] at intervals of 50 msec as a rule (although this may not be the case if the
port is being used by other communication), for a period of 10 seconds.
If Address UL= 0x7F is received, transmission of all meter data will be halted
immediately. (disable)

Transmission
If [Parameter Change ECHO] is ON, this message is retransmitted without
change.

2.12.3.25 Parameter change (Remote Time Counter)

When transmission is enabled by receiving a Request of Remote Time Counter,
the Time Counter data is transmitted every 50 msec for 10 seconds. When you
want to transmit Counter information continuously, a Request must be trans-
mitted within every 10 seconds.

Reception
This is echoed if [Parameter change ECHO] is ON.

Transmission
When transmission is enabled by receiving a Request, the Time Counter infor-
mation is transmitted on [RxCH] channel every 50 msec for 10 seconds.
Transmission will be disabled if the power is turned off and on again, or if the
PORT setting is changed.
If [Parameter Change ECHO] is ON, this message is retransmitted without
change.

2.12.3.26 Parameter request (Remote Time Counter)

Reception
This is received if [Parameter change RX] is ON and the [Rx CH] matches the
device number included in the SUB STATUS. This is echoed if [Parameter
change ECHO] is ON.
When this is received, the Time Counter information is transmitted on the [Rx
CH] channel every 50 msec for 10 seconds.
When the second byte of Address is received on 0x7F, data transmission will be
halted immediately. (disable)

Transmission
If [Parameter Change ECHO] is ON, this message is retransmitted without
change.

2.12.3.27 Parameter change

(Automix Status)

When transmission is enabled by receiving a Request of Automix status, the Au-
tomix Status data is transmitted every second for 10 seconds. When you want
to transmit the Automix Status information continuously, the Request must be
transmitted continuously minimum within 10 seconds interval. The data is
transmitted continuously while the transmission is enabled, even when the Au-
tomix Status on the DM1000 has been changed.

Reception
This is echoed if [Parameter change ECHO] is ON.

Transmission
When the transmission is set to enable by receiving a Request. The Automix Sta-
tus data is transmitted on the [Rx CH] channel every second for 10 seconds. The
data is transmitted continuously while the transmission is enabled, even when
the Automix Status on the DM1000 has been changed.
Transmission will be disabled if the power is turned off and on again, or if the
PORT setting is changed.
If [Parameter Change ECHO] is ON, this message is retransmitted without
change.

2.12.3.28 Parameter request

(Automix Status)

Reception
This is received if [Parameter change RX] is ON and the [Rx CH] matches the
device number included in the SUB STATUS.
This is echoed if [Parameter change ECHO] is ON.
When the data is received, the Automix Status data is transmitted on the [Rx
CH] every second for 10 seconds.
When the second byte of Address is received on 0x7F, data transmission will be
halted immediately (disable).

Transmission
If [Parameter Change ECHO] is ON, this message is retransmitted without
change.

STATUS

11110000 F0

System exclusive message

ID No.

01000011 43

Manufacture’s ID number (YAMAHA)

SUB STATUS

0011nnnn 3n

n=0-15 (Device number=MIDI Channel)

GROUP ID

00111110 3E

MODEL ID (digital mixer)

MODEL ID

00001100 0C

DM1000

ADDRESS

00100001 21

Remote meter

0mmmmmmm mm

ADDRESS UL

0mmmmmmm mm

ADDRESS LU

0mmmmmmm mm

ADDRESS LL

0ccccccc ch

Count H

0ccccccc cl

Count L

EOX

11110111 F7

End of exclusive

STATUS

11110000 F0

System exclusive message

ID No.

01000011 43

Manufacture’s ID number (YAMAHA)

SUB STATUS

0001nnnn 1n

n=0-15 (Device number=MIDI Channel)

GROUP ID

00111110 3E

MODEL ID (digital mixer)

MODEL ID

00001100 0C

DM1000

ADDRESS

00100010 22

Remote Time counter

0000tttt 0t

0:Time code, 1:Measure.Beat.Clock

0ddddddd dd

Hour / Measure H

0ddddddd dd

Minute / Measure L

DATA

0ddddddd dd

Second / Beat

0ddddddd dd

Frame / Clock

EOX

11110111 F7

End of exclusive

STATUS

11110000 F0

System exclusive message

ID No.

01000011 43

Manufacture’s ID number (YAMAHA)

SUB STATUS

0011nnnn 3n

n=0-15 (Device number=MIDI Channel)

GROUP ID

00111110 3E

MODEL ID (digital mixer)

MODEL ID

00001100 0C

DM1000

ADDRESS

00100010 22

Remote Time counter

0ddddddd dd

0:Transmission request,
0x7F:Transmission stop request

EOX

11110111 F7

End of exclusive

STATUS

11110000 F0

System exclusive message

ID No.

01000011 43

Manufacture’s ID number (YAMAHA)

SUB STATUS

0001nnnn 1n

n=0-15 (Device number=MIDI Channel)

GROUP ID

00111110 3E

MODEL ID (digital mixer)

MODEL ID

00001100 0C

DM1000

ADDRESS

00100011 23

Automix status

00000000 00

0000dddd 0d

Automix status H

0000dddd 0d

Automix status L

EOX

11110111 F7

End of exclusive

STATUS

11110000 F0

System exclusive message

ID No.

01000011 43

Manufacture’s ID number (YAMAHA)

SUB STATUS

0011nnnn 3n

n=0-15 (Device number=MIDI Channel)

GROUP ID

00111110 3E

MODEL ID (digital mixer)

MODEL ID

00001100 0C

DM1000

ADDRESS

00100011 23

Automix status

0ddddddd dd

0:Transmission request,
0x7F:Transmission stop request

EOX

11110111 F7

End of exclusive

This manual is related to the following products: