Oritron Dionex Ion Chromatography System ICS-2100 User Manual
Oritron Home Theater Systems
Table of contents
Document Outline
- ICS-2100 Ion Chromatography System Operator’s Manual
- Contents
- 1 . Introduction
- 2 . Features
- 3 . Operation and Maintenance
- 3.1 Operation Overview
- 3.2 Turning On the System Power
- 3.3 Connecting to Chromeleon
- 3.4 Set Up the Eluent Reservoir
- 3.5 Check All Connections
- 3.6 Prime the Pump
- 3.7 Set System Operating Conditions
- 3.8 Equilibrate the System and Verify Operational Status
- 3.9 Prepare Samples
- 3.10 Loading and Injecting Samples
- 3.11 Processing Samples
- 3.12 Maintenance
- 4 . Troubleshooting
- 4.1 Error Messages
- 4.2 Troubleshooting Error Messages
- 4.3 Liquid Leaks
- 4.4 Pump Difficult to Prime or Loses Prime
- 4.5 Pump Does Not Start
- 4.6 No Flow
- 4.7 Erratic Flow/Pressure Reading
- 4.8 Excessive System Backpressure
- 4.9 Peak “Ghosting”
- 4.10 Nonreproducible Peak Height or Retention Time
- 4.11 Abnormal Retention Time or Selectivity
- 4.12 No Cell Response
- 4.13 High Cell Output
- 4.14 Baseline Noise or Drift
- 4.15 Vacuum Degas Assembly Does Not Run
- 5 . Service
- 5.1 Diagnostic and Calibration Procedures
- 5.2 Isolating a Restriction in the Liquid Lines
- 5.3 Replacing Tubing and Fittings
- 5.4 Rebuilding the Injection Valve or Auxiliary Valve
- 5.5 Replacing an Auxiliary Valve Pod
- 5.6 Cleaning and Replacing the Pump Check Valves
- 5.7 Replacing a Pump Piston Seal and Piston Rinse Seal
- 5.8 Replacing a Pump Piston
- 5.9 Replacing the Waste Valve or Priming Valve O-Ring
- 5.10 Replacing the Conductivity Cell
- 5.11 Replacing the Suppressor
- 5.12 Replacing the Column Heater
- 5.13 Replacing the Column Heater Heat Exchanger
- 5.14 Replacing the Eluent Valve
- 5.15 Replacing the Leak Sensor
- 5.16 Priming the Pump
- 5.17 Priming the Pump with Isopropyl Alcohol
- 5.18 Changing Main Power Fuses
- 5.19 Replacing an EluGen Cartridge
- 5.20 Replacing the CR-TC
- 5.21 Replacing the EPM Electrolytic pH Modifier
- 5.22 Replacing the EGC CO3 Mixer
- 5.23 Replacing the EGC Holder and Degas Assembly
- A . Specifications
- A.1 Electrical
- A.2 Physical
- A.3 Environmental
- A.4 Front Panel
- A.5 Analytical Pump and Fluidics
- A.6 Eluent Generation
- A.7 Detector Electronics
- A.8 Conductivity Cell with Heat Exchanger
- A.9 Injection Valve
- A.10 Auxiliary Valve (Optional)
- A.11 Vacuum Degas Assembly
- A.12 Column Heater
- A.13 Auxiliary Power Supply (Optional)
- A.14 Suppressors
- A.15 Autosampler
- A.16 System Software
- B . Touch Screen Operation
- B.1 Using the Touch Screen
- B.2 Using the Touch Screen with Chromeleon
- B.3 Overview of ICS-2100 Touch Screen Pages
- B.4 Home Page
- B.5 Plot Page
- B.6 Status Page
- B.7 Pump Page
- B.8 Eluent Generator Page
- B.9 Suppressor Page
- B.10 Detector Page
- B.11 Information Page
- B.12 Module Setup Page
- B.13 Input/Output Page
- B.14 Diagnostic and Calibration Pages
- C . TTL and Relay Control
- D . Reordering Information
- E . FAQ
- E.1 How do I hook up an autosampler?
- E.2 How do I print?
- E.3 Why are the retention times moving?
- E.4 How do I adjust retention times?
- E.5 When should I remake standards?
- E.6 When should I replace the eluent generator cartridge?
- E.7 How do I start Chromeleon?
- E.8 How do I delete data?
- E.9 How do I back up data?
- E.10 How do I shut off the system?
- E.11 How do I store columns?
- E.12 How do I know when a column is dirty?
- E.13 How do I clean a column?
- E.14 Why is the conductivity high?
- E.15 How do I configure and operate the auxiliary valve?
- F . Glossary