Package contents, Power cable, Equipment needed – RAD Data comm IPmux-1 User Manual
Page 38: Installation and setup, Setting jumpers, 3 package contents, 4 equipment needed, 5 installation and setup
Chapter 2 Installation
IPmux-1/1E Installation and Operation Manual
2-2 Installation and Setup
The DC power source must be isolated from the mains supply by double or
reinforced insulation. A suitable fuse or a circuit breaker should be integrated in
the negative power-supply line.
Allow at least 90 cm (36 inches) of frontal clearance for operator access. Allow at
least 10 cm (4 inches) clearance at the rear of the unit for cable connections. Make
sure that the ventilation holes are not blocked.
The ambient operating temperature of IPmux-1/1E is 0
o
to 50
o
C (32
o
F to 122
o
F),
at a relative humidity of up to 90%, non-condensing.
2.3 Package Contents
The IPmux-1/1E package contains the following items:
• IPmux-1/1E unit
• Power cord
• Kit containing hardware for mounting the unit in a 19-in rack (optionally
supplied)
− RM-25 for IPmux-1
− RM-27 for IPmux-1E.
Power Cable
IPmux-1/1E comes equipped with the power cord connected to the AC/DC
interface on the rear panel.
2.4 Equipment Needed
IPmux-1/1E needs no special tools for installation. A screwdriver is necessary when
mounting IPmux-1/1E in a 19-in rack.
2.5 Installation and Setup
Setting Jumpers
IPmux-1
In general, IPmux-1 internal jumpers and switches do not need to be configured
by the user. Therefore, removing the product cover is not required.
Caution